RAM Concept Help

Check for punching shear

  1. Choose Layers > Design Strip > Punching Checks Plan.
  2. Double click the Punching Shear Check tool ().
  3. In the Default Punching Shear Check Properties dialog box:
    1. Change Cover to CGS to 41 mm (cover to centroid of top reinforcement).
    2. Click OK.
  4. Fence the slab with the Punching Shear Check tool.
  5. Select the punch check at 0, 15.5m and change the Beta Factor to 1.40 (edge).

Design Strip: Punching Checks Plan.