Check for punching
shear
-
Choose
Layers > Design Strip > Punching Checks
Plan.
-
Double click the Punching Shear Check tool ().
-
In the Default Punching Shear Check Properties dialog box:
-
Change
Cover to CGS to 41 mm (cover to centroid
of top reinforcement).
-
Click
OK.
-
Fence the slab with the Punching Shear Check tool.
-
Select the punch check at 0, 15.5m and change the
Beta Factor to
1.40 (edge).
Design Strip:
Punching Checks Plan.