RAM Concept Help

Define the column locations and properties

  1. Turn on Snap to Center ().
  2. Double click on the Column tool ().
  3. In the Default Column Properties dialog box:
    1. Choose a Concrete Strength of 5000 psi [32 MPa for AS3600; C32/40 for BS8110 and EC2].
    2. Set Height to 10 feet [3 m].
    3. Set Support Set to "Above".
    4. Set Width to 30 inches [750 mm].
    5. Set Diameter to 30 inches [750 mm].
    6. Check "Roller at Far End".
    7. Uncheck "Fixed Near" and "Fixed Far".
  4. Click OK.
  5. Click at the center of all 11 column locations shown on the imported drawing.