Promis.e Readme

New and Changed in Promis.e CONNECT Edition Update 8

The following items summarize the new features and enhancements in the Promis.e CONNECT Edition Update 8 release:

  • Add Jumper Display setting to control when Installation/Location/Device Tag and Wiring Address values are shown in Wiring Diagram.

    User is able to suppress display of same device connections for installation, location, and device tag attributes for wiring diagram destination strings. User is also able to specify a Jumper Connection Prefix or Suffix.

  • Add ability to configure and display cross references for cable symbols in Cable Diagram.

    Add new configuration "Cross Reference Expression" to existing cable diagrams setting dialog. The expression is user definable. When user clicks the "Build Expressions" button, a configuration dialog opens allowing the user to configure a cross reference expression.

  • Radius at cable diagram merges instead of diagonal lines.

    User is able to choose two merge types "Chamfer Merges" and "Filleted Merges" for cable diagram.

  • Add ability to maintain Device/Wire Link/Wire Numbers/Terminal Numbers for Copy from Reference file.
    Users are able to choose the following options when copying objects from a reference file:
    • Maintain Complete or Tag Only for devices, wire links, and wire numbers
    • Maintain Check box for Terminal Numbers

  • Add validation to prevent submission of items when JSON Deliveryaddress is NULL or Blank.

    Submit validation to prevent submission of items when JSON Deliveryaddress is NULL or Blank.