Here you can set the length of time a connection can be idle (not sending requests to the server) before it is closed, and also whether or not the server is to run in secure mode.

Setting Description
TimeOut Used to set how many seconds can pass without any activity from the client, before the client connection times out. The default value is 600 (seconds). This setting can also be set from the Timeouts tab of the Server Properties dialog, in ProjectWise Administrator.
MultiRequestTimeOut Used to set how many seconds can pass without activity before a multi-request operation, such as a file transfer, times out. This timeout value should be set to be greater than or equal to the longest expected file transfer time. The default value is 3000 (seconds).
WaitBusy Used to set the time, in seconds, that the request by the web client may wait on the server to get services, in the situation that the server is currently serving the same client on another operation. The default value is 0 (seconds). This setting can also be set from the Timeouts tab of the Server Properties dialog, in ProjectWise Administrator.
FileAccessTokenLifetime Lifetime (in seconds) for a per-request file system access token, generated by the ProjectWise Design Integration Server, that the ProjectWise Caching Server uses to authenticate that the request for a file is coming from a properly authenticated client login. This value may need to be increased when serving files over slow network connections, or when dealing with exceptionally large files. The default value is 180 (seconds).
StatisticsFrequency Sets how often, in seconds, that datasource statistics will be updated. The default is to update every 43200 seconds (12 hours). Set the value to 0 if you never want datasource statistics to be updated.
ACLCleanupFrequency Sets how often access control records that are flagged for deletion will be permanently removed from the database. Access control records get flagged for deletion in the database when a user (or group or user list) is removed from a document, folder, or project, or when a document, folder, or project containing access control settings is deleted. The default is to remove these flagged records every 43200 seconds (12 hours). Set the value to 0 if you never want these flagged records to be removed from the database.
FileAccessTokenMasterKey Master key used to sign networked file system access tokens. To cause all tokens to immediately expire, simply delete this entry from the DMSKRNL.CFG file.
DelegatedLoginTokenTimeout Lifetime (in seconds) for credentials used to impersonate another user. The default value is 36000 seconds (10 hours). Set the value to 0 if you never want the token to expire.
UserLoginTokenTimeout Lifetime (in seconds) for client-side cached login credentials, used to silently re-authenticate a client to the ProjectWise Design Integration Server in the event of a network disconnect. When using ProjectWise authentication, after this timeout occurs clients will be required to re-input their ProjectWise login credentials. The default value is 36000 seconds (10 hours). A value of 0 (or less) is illegal. Configure the user setting, Credential expiration policy, in ProjectWise Administrator, to set the policy for user expirations. If this setting is commented out, a default expiration value of 10 hours is used. Note that this applies to ProjectWise authentication only: cached SSO/domain login credentials are not expired.
LoginTokenMasterKey1 LoginTokenMasterKey2 Master keys used to sign login tokens. To cause all login tokens to immediately expire, simply delete these entries from the DMSKRNL.CFG file.
SecureConnection Uncomment this setting (and leave the value set to 1) to run the server in secure mode. This setting can also be set from the Connection tab of the Server Properties dialog, in ProjectWise Administrator.
SecureCertificateCommonName Uncomment this setting and after the = character, enter the common name (CN) of your certificate, when running the server in secure mode. This setting can also be set from the Connection tab of the Server Properties dialog, in ProjectWise Administrator.
FileTransferSrv Uncomment this setting (and leave the value set to 1) to configure this server as a ProjectWise Caching Server. Note that Caching Server behavior is enabled by default when running in Integration Server mode (the default mode). Activating this setting on a ProjectWise Design Integration Server has the practical effect of deactivating Integration Server functionality.
ConnectionSrv Uncomment this setting (and leave the value set to 1) to activate the ProjectWise Gateway Service (gateway and routing) features of this server.
ServerName

ServerIPAddress

Used to set the name and IP address to use when advertising the server. When running in a clustered environment, set these values to the cluster name and cluster IP address.
ExtractionServers

ExtractionTokenLifetime

Extraction processes usually hang on to filesystem access tokens after their default expiration (see FileAccessTokenLifetime, above). If you are running extractions, use the first setting (ExtractionServers) to specify the host computers (which must also be specified in the Trusted Server section of this DMSKRNL.CFG file) that the extraction processes will be running on, then set a value (in seconds) for the second setting (ExtractionTokenLifetime) so that those trusted servers have an extended file access token window (lifetime).
Databases Displays a comma separated list of the ProjectWise Design Integration Server's databases.
CADOperators List of Windows users/groups that are permitted to make remote configuration changes to this DMSKRNL.CFG file (typically from ProjectWise Administrator). Users that will be creating, deleting or changing basic datasource properties (like ODBC settings, datasource name, and so on) are required to either be explicitly listed here, or to belong to a group that is listed here. Note that this level of access is not required to perform normal ProjectWise administrative tasks (such as adding users, setting up User Synchronization Service, managing storage areas and so on).
LogLicenseToWindowsEventLog Controls whether or not an informative message is sent to the Windows event log every time the server license is renewed. Uncomment and set to 0 if you do not want an informative message is sent to the Windows event log every time the server license is renewed.