ProjectWise Administrator Help

ProjectWise Analytics Data Upload Service Requirements

Product Version

ProjectWise Analytics Data Upload Service, version 01.00.01.88

This version contains important performance improvements. If you have a previous version installed, make sure you uninstall it and use this newer version instead.

Download the service from here: https://softwaredownloads.bentley.com/en/ProductDetails/2350

Note: This version is newer than the version delivered with ProjectWise Admin Setups CONNECT Edition Update 3.2 refresh 2 (10.00.03.280) and ProjectWise Admin Setups CONNECT Edition Update 3.3 (10.00.03.329).

Operating Systems

  • Windows Server 2016
  • Windows Server 2012 R2
  • Windows Server 2012
  • Windows Server 2008 R2 SP1
  • Windows Server 2008 SP2

Prerequisites

  • Microsoft .NET Framework 4

Database Connections

You can establish a connection to the following databases:

  • ProjectWise database (required)
  • Bentley Transmittal Services V1.0 database (optional)

The ProjectWise database can be from the following ProjectWise versions:

  • ProjectWise CONNECT Edition Update 3.2 refresh 2 (10.00.03.280)
  • ProjectWise CONNECT Edition Update 3.2 refresh 1 (10.00.03.271)
  • ProjectWise CONNECT Edition Update 3.2 (10.00.03.262)
  • ProjectWise CONNECT Edition Update 3.1 (10.00.03.140)
  • ProjectWise CONNECT Edition Update 3 (10.00.03.49)
  • ProjectWise CONNECT Edition Update 2.2 (10.00.02.265)
  • ProjectWise CONNECT Edition Update 2 (10.00.02.96)
  • ProjectWise CONNECT Edition Update 1.1 (10.00.01.67)
  • ProjectWise CONNECT Edition Update 1 (10.00.01.25)
  • ProjectWise CONNECT Edition (10.00.00.20)
  • ProjectWise V8i (SELECTseries 4) (08.11.11.559 or 08.11.11.590)

ProjectWise Analytics Data Upload Service supports the same SQL Server and Oracle versions that are supported by ProjectWise Design Integration Server and Bentley Transmittal Services.

Important: ProjectWise Analytics Data Upload Service collects and stores change baseline information in the same ProjectWise and Bentley Transmittal Services databases that you make connections to. This information is not stored in the ProjectWise and Bentley Transmittal Services tables, but rather is copied in advance from the ProjectWise and Bentley Transmittal Services tables and then cached in separate ProjectWise Analytics Data Upload Service tables. This can cause the database to significantly increase in size (up to twice the original size). Make sure the database server has enough space to accommodate this growth.

Ports

ProjectWise Analytics Data Upload Service uses the following ports through which it collects and uploads data:

[TCP:1433] ProjectWise Design Integration Server - default port used for SQL Server database
[TCP:1521] ProjectWise Design Integration Server - default port used for Oracle database
[TCP:1433] Bentley Transmittal Services - default port used for SQL Server database
[HTTPS(443)] Bentley Identity Management Service (https://ims.bentley.com/)
[HTTPS(443)] ProjectWise Project Insights service (https://projectinsights.bentley.com/)
[HTTPS(443)] ProjectWise Project Performance Dashboards service (https://connect-analytics.bentley.com/)

Supported Browsers

  • Microsoft Edge
  • Microsoft Internet Explorer 11 (32-bit only)
  • Google Chrome (latest version) on Windows

Supported ProjectWise Explorer Versions

You can associate a work area to a ProjectWise project using any of these versions of ProjectWise Explorer:

  • ProjectWise Explorer CONNECT Edition Update 3.3 (10.00.03.329)
  • ProjectWise Explorer CONNECT Edition Update 3.2 refresh 2 (10.00.03.280)
  • ProjectWise Explorer CONNECT Edition Update 3.2 refresh 1 (10.00.03.271)
  • ProjectWise Explorer CONNECT Edition Update 3.2 (10.00.03.262)
  • ProjectWise Explorer CONNECT Edition Update 3.1 refresh (10.00.03.167)
  • ProjectWise Explorer CONNECT Edition Update 3.1 (10.00.03.140)
  • ProjectWise Explorer CONNECT Edition Update 3 (10.00.03.49)
  • ProjectWise Explorer CONNECT Edition Update 2.3 (10.00.02.320)
  • ProjectWise Explorer CONNECT Edition Update 2.2 (10.00.02.265)
  • ProjectWise Explorer CONNECT Edition Update 2.1 (10.00.02.203)
  • ProjectWise Explorer CONNECT Edition Update 2 (10.00.02.96)
  • ProjectWise Explorer CONNECT Edition Update 1.2 (10.00.01.71)
  • ProjectWise Explorer CONNECT Edition Update 1.1 (10.00.01.67)
  • ProjectWise Explorer CONNECT Edition Update 1 (10.00.01.25)
  • ProjectWise Explorer CONNECT Edition (10.00.00.20)
  • ProjectWise Explorer V8i (SELECTseries 4) (08.11.11.559 or 08.11.11.590) with the ProjectWise Explorer Cloud Integration Module installed