Rat Hole
|
When checked, a Rat Hole is applied end of the
connecting member.
- Web
Gap – Sets the gap from the end point of connecting shape to the
web.
Note: This
distance is in addition to the gap between the connecting and supporting
members.
- Flange
Gap (Upper / Lower) – Sets the gap (additional distance) from the
end point of connecting shape to the flanges.
- Upper /
Lower Depth – Sets the depth of the bevel applied to the flanges.
- Upper /
Lower Angle – Sets the angle of the bevel applied to the flanges.
- Invert
(Upper / Lower) – When checked, the bevel is inserted on the
opposite side of the flange.
- Chamfer/
Fillet/ Cope (Inserted Arc) – When checked, sets the respective
type of cut for the access hole applied to the web.
- Upper/
Lower Chamher – For
Chamfer option, the value equally sets the
rise and run of the chamfered access hole applied to the web.
- Upper/
Lower Radius – For
Fillet and
Cope options, the value sets the radius of the
access hole applied to the web.
- Upper/
Lower Web Distance – For
Cope option, this value allows the access hole
to be shifted to the right or left relative to the Web Gap.
|
Web Plate
|
Note: This option is
only available when the Moment plates are inline with the flanges or not used
at all.
- Upper /
Lower Plate – When checked, sets the upper/lower or both weld
plates be placed below the flanges.
- Length/
Width / Thickness – Sets the length, width and thickness
respectively of the weld plates. Enabled when one of the weld plate or both
options are set.
|