ProStructures Help

Web Moment Connection - Rat Hole tab

Used to set the rat hole consists of web and flange gaps, bevels applied to the flanges and access holes applied to the web.


Note: To enable Rat Hole settings, ensure the Beam Between Moments is unchecked.
SettingDescription
Rat Hole When checked, a Rat Hole is applied end of the connecting member.
  • Web Gap – Sets the gap from the end point of connecting shape to the web.
    Note: This distance is in addition to the gap between the connecting and supporting members.
  • Flange Gap (Upper / Lower) – Sets the gap (additional distance) from the end point of connecting shape to the flanges.
  • Upper / Lower Depth – Sets the depth of the bevel applied to the flanges.
  • Upper / Lower Angle – Sets the angle of the bevel applied to the flanges.
  • Invert (Upper / Lower) – When checked, the bevel is inserted on the opposite side of the flange.
  • Chamfer/ Fillet/ Cope (Inserted Arc) – When checked, sets the respective type of cut for the access hole applied to the web.
  • Upper/ Lower Chamher – For Chamfer option, the value equally sets the rise and run of the chamfered access hole applied to the web.
  • Upper/ Lower Radius – For Fillet and Cope options, the value sets the radius of the access hole applied to the web.
  • Upper/ Lower Web Distance – For Cope option, this value allows the access hole to be shifted to the right or left relative to the Web Gap.
Web Plate
Note: This option is only available when the Moment plates are inline with the flanges or not used at all.
  • Upper / Lower Plate – When checked, sets the upper/lower or both weld plates be placed below the flanges.
  • Length/ Width / Thickness – Sets the length, width and thickness respectively of the weld plates. Enabled when one of the weld plate or both options are set.