Used to specify settings for modification control.

SettingDescription
Length Tolerance Sets the tolerances to be used for comparing the component parts. You can specify the values for line length as well as the comparison of drill holes, lengths and weight.

Modifications are determined by means of a type of comparison which is also used for positioning.

Single Parts
  • At Changes – Sets the behavior of the single part position number at a changed part.
    • Don't delete Position Number (Keep) – The position number is not changed.
    • Ask to delete Position Number (Confirm) – The position number is only deleted if this is individually confirmed for each part.
    • Delete Position Number (Delete) – The position number is always deleted.
  • Storing the position number – Sets what has to happen with the invalid (former) position number at a changed single part. Disabled for Delete Position Number option.
    • Don't Save the Position Number (No Storing) – The position number is not changed.
    • Ask to Saving Position Number (Confirm) – The position number is only stored as original position if this is individually confirmed for each part.
    • Store Position Number (Save) – The position number is saved as original position.
Groups Sets the behavior of the group position number at a changed part. The possible specifications correspond to those for Single Parts and are described there.
Set modify flag when pos number When set, the modification flag is turned "ON" whenever there is valid modification to part irrespective of having or not "Position Number".