Values
|
|
Cuts
|
- Parallel
to Cut Plane – When checked, the connecting shape's flange is cut
parallel to the edge of the supporting shape. Otherwise, the flange gap is cut
perpendicular to the direction of the connecting shape.
- Top /
Bottom Flange Gap – Sets the gap distance between the supporting
shape's flange and the connecting shape's flange.
- Cope – When
checked, the connecting shape is coped from the web of the supporting shape by
the selected cope template.
- Cope
Template – Enabled for
Cope, selectable from templates
available in the drop-down list.
- Normal to
Cut Plane – When checked, the connecting bolts are set
perpendicular to the supporting shape.
- Flip – When
checked, the Stiffener Plate is placed of the opposite side on the connecting
shape.
|
Group
|
-
Group – When checked, the entire connection, including the
connecting shape, is assigned to a construction group. If the shape is already
part of another component group, the connection will be assigned to the same
group.
- With
Bolts - When checked, the bolts are also added to that group.
|