Intra-Plant Spacing
Intra-plant spacing is one type of proximity type; users taking advantage of the proximity check functionality will need this table (see Proximity Checking).
Intra-plant-spacing values are in master units (feet or meters).
EQUIP | Cond | Pw | Heat | RunDn | P-Hi | P-Int | R-Hi | R-Int | R- Mod | Common |
---|---|---|---|---|---|---|---|---|---|---|
COMMON | 10.0 | 40.0 | 20.0 | 60.0 | 30.0 | 30.0 | 50.0 | 50.0 | 50.0 | 70.0 |
COND | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 5.0 | 15.0 | 10.0 | 5.0 | 10.0 |
HEAT | 15.0 | 20.0 | 0.0 | 30.0 | 10.0 | 5.0 | 15.0 | 10.0 | 5.0 | 20.0 |
P-HI | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 15.0 | 10.0 | 10.0 | 10.0 | 30.0 |
P-INT | 5.0 | 5.0 | 5.0 | 5.0 | 15.0 | 5.0 | 5.0 | 5.0 | 5.0 | 30.0 |
PW | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 5.0 | 15.0 | 10.0 | 5.0 | 40.0 |
R-HI | 15.0 | 15.0 | 15.0 | 15.0 | 10.0 | 5.0 | 15.0 | 15.0 | 15.0 | 50.0 |
R-INT | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 5.0 | 15.0 | 10.0 | 10.0 | 50.0 |
R-MOD | 5.0 | 5.0 | 5.0 | 5.0 | 10.0 | 5.0 | 15.0 | 10.0 | 5.0 | 50.0 |
RUN-DN | 10.0 | 10.0 | 30.0 | 45.0 | 10.0 | 5.0 | 15.0 | 10.0 | 5.0 | 60.0 |