PlantWise Help

Table 6: Missing Data Exception Messages

Any data missing from a table-lookup during routing generates a Missing Data exception.

Category Message
Missing Data Could not find a value in the lateral table <tag> for a run/branch diameter (<size>/<size>) to determine the <attribute>. Using the center to end for a Tee as a default.
Missing Data Could not find the lateral table <tag> to determine the <attribute>. Using the center to end for a Tee as a default.
Missing Data Diameter <size> and insulation thickness <size> are not listed in the cradle-dimensions table, using 0.0 as the cradle thickness.
Missing Data Missing outer diameter for <size> diameter in dpar-pipe-size-properties table; using the nominal diameter.
Missing Data Missing weld neck length for <size> diameter pipe at nozzle <tag> with rating <rating>, assuming 0.0
Missing Data Need 45-degree elbow dimensions for a <size> diameter pipe, which are not in the dpar-pipe-size-properties table; assuming <0.625 * diameter> for center-to-end-distance
Missing Data No tee center-to-end distance in the dpar-pipe-size-properties table for the tee with diameter <size> on Pipeline <tag> from Pipeline <tag>; assuming a size of <size>
Missing Data No tee type was found in the Branch table (<tag>). Defaulting to a straight tee.
Missing Data No value was found (or value was of incorrect type) in the dpar-pipe-material-expense table indicating whether the material <material type> for Pipeline <tag> is expensive. For the purposes of determining routing order, the router will assume that it is NOT expensive.
Missing Data The changed line class <class code> is not defined in the dpar-pipe-class-properties table.
Missing Data There is no flange diameter in the dpar-pipe-rating-properties table for a pipeline with diameter <size> and rating <value>; using <size> instead
Missing Data Thermal expansion coefficient missing from table for material <material type> at temperature = <value>
Missing Data Unable to look up data for actuator height, assuming <value>. Please check dpar-control-valve-properties table.
Missing Data Unable to look up data for manifold height, assuming <value>. Please check the B-WithFins column in the dpar-control-valve-properties table.
Missing Data Unable to look up data for manifold width, assuming <value>. Please check the A column in the dpar-control-valve-properties table.
Missing Data Unable to look up data for valve width, assuming <value>. Please check the Y column in the dpar-control-valve-properties table.
Missing Data Unknown reducer size <size>x<size> for line <tag>; assuming reducer length <value>
Missing Data Warning: There is no flange diameter in the dpar-pipe-rating-properties table for the <size> diameter of line <tag> at this flow element component, using default formula value <value>
Missing Data Warning: There is no weld neck length in the dpar-pipe-rating-properties table for the <size> diameter of line <tag> at this flow element, using default formula value <value>