Table 8: Placement Error Exception Messages

Whenever the AutoRouter cannot place an inline component, boundary, or expansion loop according to placement rules, a Placement Error exception is reported.

Category Message
Placement Error Cannot place calculated loop for Pipeline <tag> near <location> on pipeway <tag> - too many loops or obstructions at required location.
Placement Error Cannot place user loop for Pipeline <tag> at <location> of pipeway <tag> - because another user loop in the opposite orientation exists at this location.
Placement Error Cannot place user loop for Pipeline <tag> at <location> of pipeway <tag> - flat loop cuts other lines.
Placement Error Cannot place user loop for Pipeline <tag> at <location> of pipeway <tag> - insufficient space for all loops at this location.
Placement Error Cannot place user loop for Pipeline <tag> at <location> of pipeway <tag> - loop height does not match other loops' heights.
Placement Error Cannot place user loop for Pipeline <tag> at <location> of pipeway <tag> - loop is too wide.
Placement Error Cannot place user loop for Pipeline <tag> at <location> of pipeway <tag> - loop site is not available.
Placement Error Cannot place user loop for Pipeline <tag> at <location> of pipeway <tag> due to obstruction.
Placement Error Cannot place user loop for Pipeline <tag> at <location> of pipeway <tag> - pipeline has a tee at the loop location.
Placement Error Can't place a PSV off a downward nozzle.
Placement Error Could not determine which pipeline segment the inline <tag> should be placed on.
Placement Error Flow element <tag> spacing of <tag> is less than required spacing of <value>
Placement Error The <upstream | downstream> spacing of <value> is less than the requested spacing of <value>.
Placement Error The boundary does not have an associated pipeway. The location cannot be determined.
Placement Error The boundary's orientation relative to its other end makes it impossible to position.
Placement Error The calculated value, <value>, for <attribute name> of <user inline class> is invalid. Check the rule: <expression> and any attributes/components it references. The default class value for this attribute, <value>, will be used instead.
Placement Error The end-of-pipeway is attached to pipeway <tag>, which doesn't exist in the current model.
Placement Error The location for the outlet boundary cannot be determined. The prerequisite that its other end be placed is not satisfied.
Placement Error The on-pipeway router was unable to place one or both of the tees at the ends of this pipeline. Try rerouting only the branch line or freezing the tees on the main pipeline and rerouting.
Placement Error The pressure safety valve cannot be placed because the route for Pipeline <tag> is unavailable.
Placement Error There is a problem in placement sequencing of this inline component along this Pipeline (<tag>), probably due to previous placement errors.
Placement Error There was an error in the Geometry Description of <tag>.
Placement Error Unable to compute a location for a pressure safety value where the inlet pipeline does not begin as a nozzle or tee.
Placement Error Unable to compute a location for a pressure safety value with inlet Pipeline <tag> branching off Pipeline <tag>, which doesn't leave the pipeway.
Placement Error Unable to compute a location for the pressure safety value.
Placement Error Unable to compute a location for the tee to the pressure safety value's inlet pipeline.
Placement Error Unable to find enough space on Pipeline <tag> to place this component, and all default placement alternatives failed.
Placement Error Unable to find enough space on Pipeline <tag> to place this component, placing it off the Pipeline at [<coordinate set>, <coordinate set>].
Placement Error Unable to honor the requested segment preference of <horizontal | vertical> in component placement.
Placement Error Unable to place flow element on line <tag>
Placement Error Unable to place flow element properly on line <tag>, placing it at <coordinate set>
Placement Error Unable to place inline at ends or along pipeways. PlantWise will attempt to place as a slideable component.
Placement Error Unable to place this component on the routed Pipeline <tag>.
Placement Error Unable to place this tee on the routed Pipeline <tag>.
Placement Error User loop in Pipeline <tag> for pipeway <tag> at <location> - invalid location