Known Issues
Known issues of OpenPlant Support Engineering CONNECT Edition Update 10.
Description | Resolution |
---|---|
Component Manipulator changes do not get Check-in/Check-out with Plantsight. | Change coordinates orientation from Geometry
tab in Properties dialog.
OR Add the following line in opm.cfg file located at " C:\Program Files\Bentley\OpenPlant CONNECT Edition\OpenPlantModeler\config\appl\opm.cfg" OPSE_MODIFY_TIME_PROP_NAME = LastModifiedTime Add the following line in
OpenPlant_3D.01.08.ecschema.xml under
ECClass GraphicalComponent
<ECClass typeName="GraphicalComponent" description="Engineering Supports RootClass" displayLabel="Engineering Supports" isDomainClass="False"> <ECProperty propertyName="LastModifiedTime" typeName="dateTime" description="Update Last Modify time" displayLabel="Last Modified Time" /> |
OpenPlant Modeler move component command for Pipe with OpenPlant Support Engineering Support does not get Check-in/Check-out. | Use Microstation move command while doing move operation for OPSE Supports in Plantsight connected mode. |
Checking-out in new dgn and then check-in breaks connection between Pipe and Support, does not move OpenPlant Support Engineering Support components. | N/A |
OpenPlant Support Engineering support when moved/manipulated does not update the modified time property when connected with Plantsight. | N/A |
OpenPlant Support Engineering support graphics duplicated when moving the host pipe for a pipe attachment-frame assembly when connected with Plantsight. | N/A |
Frame Modify changes are not getting check-in/check-out with Plantsight. | N/A |