To Place a Pump
-
Select a pump from Pumps taskbar. (Example: Horizontal Centrifugal Pump)
Note: The Pump User Cell placement procedure is a little different than a standard pump option. Please see the How To on this procedure for more information.
-
Pick a point in the drawing for the pump, or enter the coordinates for the insertion point.
The component is placed in the drawing.
-
Enter the mirror point by picking a point either to the right or left of the pump.
This determines the direction of the discharge port. The Properties dialog opens.
- Define the Tag Number for the pump, or accept the default number.
- In the Properties section, define the property values for the pump.
- Press OK.
-
Next either:
- Pick a point in the drawing to place the tag number annotation for the pump.
- Right-click to complete the placement and terminate the command.