DWG Workmode Capability Variables

In addition to set a workmode, you can use a configuration file to control the capabilities (functions) that are enabled or disabled in a specific workmode. The workmode.cfg file describes the syntax that you can use to control various capabilities. The capability variables are listed in the capability.list file.

The default location for these files is ..\Bentley\MicroStation <version>\MicroStation\config\system\ .

Within a configuration file, a capability may be enabled or disabled using the following syntax:

<WORKMODE VARIABLE> <Operator> <Prefix> <CAPABILITY_NAME>

where:

  • <WORKMODE VARIABLE> sets the workmode for the file. For example, _USTN_CAPABILITY means that the capability variable applies to all workmodes, including V8 and DWG.
  • <Operator> appends (>) or prepends (<) the capability variable value to the workmode variable.
  • <Prefix> indicates whether the function is to be enabled (+) or disabled (-).