If you drag a reducer to a run on right or
left side of reducer sometimes sets IsTagReserved flag to false.
Note: The same
issue would occur with and data change, also with Move command.
|
- Delete reducer.
- Place new
reducer at desired location.
|
- Start
OpenPlant PID in offline mode.
- Upgrade linked
V8i files.
- Exit and
relaunch OPPID in online mode.
- Upgrade both
files.
- Synchronize
files with PlantSight.
- Select page
connector and right click to follow.
An error will occur if linked file is
synched first.
|
Upgrade while working online
(i.e. - connected to PlantSight)
|
Tag Number is added twice in
Explorer's Details dialog and all properties shown. This is noticed when you
right-click tag number from the Explorer's dialog and select details.
|
Do not use the Explorer's
Details dialog. Use Properties dialog instead.
|
When working in a
ProjectWise Managed workspace, the
Component Manager crashes on defining or editing annotations from Component
Manager.
|
Use the
File > Close of .celfile then
File >Open of previous dgnfile,
instead of the
Navigate to previous icon.
|
Instrument line does not move
when you drag a run.
|
After you drag the run, drag
instrument line, from either end, to reconnect to instruments.
|
A "Document name is reserved"
error message displays on opening document which has been freed earlier.
|
On drawing close, have
ProjectWise check file in.
|
Nozzle tag not updated in
Explorer when updating an equipment tag via browser Properties.
If an equipment tag is updated in Explorer, any
nozzle tags do not update to reflect new name.
|
Use Explorer Refresh to
update nozzle tags.
|
Off page model name is blank if you undo a
deleted page connector.
Delete linked page connector is allowed if
user isn't in a "middle" page for the connected pipe run. If at one of the end
pages, a confirmation dialog is displayed. It warns that the pipeline and pipe
run will become new instances. Be sure you really want to delete that page
connector. If press
Yes and later try to Undo, it will
corrupt the pipe run.
|
- Place new page
connector at end of pipe run.
- Right-click
Connect to Existing and pick the
originally linked page connector. The one user was trying to recover.
|
Errors inserting bypass
assembly. Inserting a bypass assembly with data changes can corrupt the run.
Until this is fixed, if any data changes are involved, the bypass assembly
creation is disabled.
|
N/A
|
DWG
Mode: DWG Mode is not supported. Therefore none of the *forAP*
WorkSets are supported.
|
|
Upgrade V8i
Project: Upgrading V8i projects have the following issues:
- Issue with
instrument levels
- In
OpenPlant PID V8i, open the level dgnlib file.
- Select Level
Manager.
- Select File
> Export and save to a .csv file.
- Open the
exported .csv file in Excel.
- Select all
of the numbers in the Number column.
- Press Delete
on the keyboard.
- Save the
.csv file.
- Select Level
Manager.
- Delete all
of the levels except
"Default."
- Select File
> Import.
- Select all
levels for import then click
OK.
Levels have been re-added tothe dgnlib
without level numbers.
- Upgrade
workspace\project.
- OpenPlant Project Administrator only handles imperial and
Metric upgrades. Any other projects (ISO,*_forAP, user) will require user
intervention:
-
Copy appropriate base
OpenPlant_PID_Supplemental_Design schema from:
C:\ProgramData\Bentley\OpenPlant Project
Administrator CONNECT
Edition\Configuration\Workspaces\WorkSpace\WorkSets\OpenPlantMetric\Standards\OpenPlant\PID_ISO\Schemas.
or whichever workset is desired. The
directory names start with "PID_".
- Perform the
project upgrade in
OpenPlant Project Administrator.
- Manually
merge your customizations into Open_PID_Supplemental_Design.
|
|
When you define a new association in the
OpenPlant Project Administrator then
open
OpenPlant PID and assign values to the association, a number of error
messages display:
See steps below:
- Open the
OpenPlant Project Administrator and
in a WorkSet, click the
OpenPlant PID node and then the Schema Editor option.
- Define a new
class under the Plant Breakdown Element node.
- Define a
relationship such as:
- Source =
Test200
- Target =
Named Item
- Add an
association, first Adding the pipeline from the + sign and then DRAGGING and
DROPPING it under Test200: (Pick the relationship defined earlier when the
relationship pop up appears) Such that Pipeline is under Test2.
- Launch
OpenPlant PID and assign values to the Test200 association.
- Try to place a
pump.
- Notice the
number of error messages appear in the message center.
|
N/A
|
Annotation for pipeline does
not get updated if the Associated Items are changed from Properties dialog.
|
N/A
|
Inline flow Elements will be
displayed each time in ''Drawing to Plant Sight Differences" dialog on every
synchronization.
|
N/A
|
Reducer will be displayed
each time in "Drawing to Plant Sight Differences" dialog after modifying the
Pipe Run Size.
|
N/A
|
Generic temporary value for
nozzle is displayed in Explorer, if Explorer is already launched on Nozzle
placement.
|
Use Explorer Refresh to
update nozzle tags
|