To Place a Tee
-
Select the Tee option from the Fittings taskbar.
The tee is ghosted onto the cursor.
-
Place the tee where the man pipe run and branch intersect.
The tee will automatically align the branch end accordingly.
Place Tee then Add the Branch Run
-
Select the Tee option.
-
Select the placement point on the main pipe run.
-
Select the direction of the branch end.
-
In the Place Pipe Run dialog, define the pipe run settings such as Flow Direction (Location), Auto-Routing options etc.
-
Route the pipe run using the standard routing procedure.
-
When finished routing the run, right-click to display the Properties dialog.
-
Define the tag number and size for the branch run.
-
Click OK to complete the procedure.