Known Issues
Known issues of OpenPlant PID CONNECT Edition.
Description | Resolution |
---|---|
Upgrade while working online (i.e. - connected to PlantSight) | |
Tag Number is added twice in Explorer's Details dialog and all properties shown. This is noticed when you right-click tag number from the Explorer's dialog and select details. | Do not use the Explorer's Details dialog. Use Properties dialog instead. |
When working in a ProjectWise Managed workspace, the Component Manager crashes on defining or editing annotations from Component Manager. | Use the File > Close of .celfile then File >Open of previous dgnfile, instead of the Navigate to previous icon. |
Instrument line does not move when you drag a run. | After you drag the run, drag instrument line, from either end, to reconnect to instruments. |
A "Document name is reserved" error message displays on opening document which has been freed earlier. | On drawing close, have ProjectWise check file in. |
Nozzle tag not updated in
Explorer when updating an equipment tag via browser Properties.
If an equipment tag is updated in Explorer, any nozzle tags do not update to reflect new name. |
Use Explorer Refresh to update nozzle tags. |
Off page model name is blank if you undo a deleted page connector. Delete linked page connector is allowed if user isn't in a "middle" page for the connected pipe run. If at one of the end pages, a confirmation dialog is displayed. It warns that the pipeline and pipe run will become new instances. Be sure you really want to delete that page connector. If press Yes and later try to Undo, it will corrupt the pipe run. |
|
Errors inserting bypass assembly. Inserting a bypass assembly with data changes can corrupt the run. Until this is fixed, if any data changes are involved, the bypass assembly creation is disabled. | N/A |
DWG Mode: DWG Mode is not supported. Therefore none of the *forAP* WorkSets are supported. | |
Upgrade V8i
Project: Upgrading V8i projects have the following issues:
|
|
When you define a new association in the OpenPlant Project Administrator then open OpenPlant PID and assign values to the association, a number of error messages display: See steps below:
|
N/A |
Annotation for pipeline does not get updated if the Associated Items are changed from Properties dialog. | N/A |
Generic temporary value for nozzle is displayed in Explorer, if Explorer is already launched on Nozzle placement. | Use Explorer Refresh to update nozzle tags |
While using Project Reuse workflows, if default options are overridden in File Conflict Resolution Dialog, then you might face synch errors within OpenPlant PID while synching data to Plant Sight. | Use the default options in the File Conflict Resolution dialog whenever the document is opened after copy/moved/renamed. |
Message center might displays
message as
Couldn't push changes to PlantSightif multiple users are performing synchronization at the same time. |
Close OpenPlant PID session, relaunch it, and refresh the BIM file. Unreserve Tags first using Engineering Data Manager's Clean Tag Register functionality and then perform synch operation in OpenPlant PID . |
If multiple users are synchronizing same WBS items/ Duplicate Tags, then there might be a chance that some tags get reserved and a synch error happens for some user in OpenPlant PID . | Browse to OpenPlant PID , pull the latest changes from the Tools buttons in Standard Preferences. | tag register and release the tag. In
If pipeline type is changed e.g. from Major to Minor and then synchronization is performed- then synch errors will be displayed. | If you need to change the pipeline type delete it, draw a new one of the correct type, and then perform a synchronization operation. |
If Pipe Run is only copied and then synchronization is performed, the program might run into synch errors. | Pipe Line should be copied along with the Pipe Run and then synchronization should be performed. |
If OpenPlant PID session is launched from OpenPlant Project Administrator and synchronization is performed, then errors will be displayed. | Launch the application from the desktop shortcut and then perform the synchronization. |
Uninstalling OpenPlant PID might uninstall OpenPlant Project Administrator if OpenPlant Project Administrator is present on the same machine. | You will need to reinstall OpenPlant Project Administrator . |
When syncing a document to PlantSight the flow orifice plates appear in the differencing dialog for previously placed orifices. | Click here to check the resolution. |
When linking 3D Pipeline Tags with OpenPlant PID using Link All button, synchronization is successful but bad request error might occur in the message center . | This error has no actual negative side effect, and the message should be ignored. |