Open Table Section Manager.
-
Choose a section catalog from the Standards drop down.
Selecting a section catalog refreshes the other Section Catalog settings.
-
Choose a catalog revision number from the Revisions drop down.
-
Choose a manufacturer (if available) from the Manufacturers drop down.
-
Press Query to apply the section catalog selections to the Sections list.
Refreshes the Section Type setting and Sections list based on the selections made so far.
-
Choose a section type from the Section Type drop down.
Refreshes the Sections list with the selected section sub types.
-
Double click a section from the Sections list.
The section is added to the Available Sections tree.
Sections added here are copied from the Structural Property Catalog to the active dgn.