To Check Connectivity on Piping Components
- Click the Check Connectivity icon from the Piping ribbon.
- Optional: If you want run the Connectivity Checker on individual pipelines, open the Pipeline Manager to run the connectivity tool on the selected pipeline.
- The Connectivity Checker dialog displays listing the connection information for the components in the model. Disconnects are flagged with a red box next to the component and the details of the disconnect are displayed in the pane below it.
- If disconnects exist that can be repaired, use the Fix Disconnects button to repair any disconnects listed.