Method
|
Sets the method for the lap, selected one from the
three options:
Length,
Bar Diameter, and
Mechanical Device.
|
Lap Length / Multiplier
|
When
Length is selected as the Lap Method , this
value set in the adjacent field will be used for bar laps.
When
Bar Diameter is selected as the Lap
Method, then type to use and the calculated lap length is shown in the
Multiplier field.
It is disabled for
Mechanical Device method.
|
Method: Mechanical Device
|
Mechanical Device method enables the Manufacturer
/Device settings:
- Manufacturer –
Sets All or one of the Manufacturers from the drop-down list.
- Type – Displays
the types of laps, lists valid categories for rebar mechanical device
selection:
- Anchorage
- Coupler
- Form Saver
- Jacks
- PT-Bars
- Terminator
You can set All or one of the Types to narrow the devices
list.
- Device – Lists
the devices in a given type for the selected manufacturer. Select required
device from the list to proceed lap settings.
When a selected component, e.g. the EL20A2
Erico Lenton A2 Standard Coupler is used, it retrieves the component’s geometry
(in binary format as DGN), graphical and business properties as stored in
Component Center. The respective fields get filled and the mechanical device is
ready for placement.
- Application –
Lists the application areas: e.g. Manufacturer, Shop, Field etc.
- Reverse – When
checked, reverses the orientation of the device on the bar end.
- Cost – Sets the
cost for the selected device type.
- Type – Sets a
device type from the drop-down list.
-
Holdback – When checked, allows setting
the hold back value to include as a length at the end of the bar with no
preparation, using the specified length value in the adjacent field
- Cost – Sets the
cost for the selected device type.
|