Isometrics Manager Batch Arguments
The user will create a command file, command key-in or shortcut. You can then provide username and password to automatically log in to ProjectWise, and specify a directory location where the i-models are stored. OpenPlant Isometrics Manager will automatically start connecting all i-models in the given directory and the connections will be presented in the component tree browser. The startup dialog is not shown.
Command Line Arguments
Argument | Usage |
---|---|
-wc<> |
OPIM configuration file
Optional: If this argument is not specified, OPIM identifies it from registry. e.g. -wc"%srcOPIM%config\opimStartUp.cfg" |
-wp | MicroStation Project Name |
-ws"SOURCE=AUTOPLANT" |
AutoPLANT source If this argument is specified application will start in AutoPLANT mode. Plant Framework installation is mandatory otherwise it will throw an error. If this argument is specified and '-wsAP_PROJID' is not specified, then AutoPLANT start-up dialog will be shown. |
-ws"SOURCE=OPENPLANT" |
OpenPlant Source If this argument is specified application will start in AutoPLANT mode. Plant Framework installation is mandatory otherwise it will throw an error. This will make application to start in OpenPlant mode. If ProjectWise arguments are specified, then application will logged-in ModelServer. |
-ws _USTN_PROJECTSROOT=<> |
MicroStation Root
Directory
Optional: e.g. -ws"_USTN_PROJECTSROOT= D:\Development\Output\PowerOPIM\Bentley\WorkSpace\Projects\/" |
-ws"PW_REPOSITORY=<>" | ProjectWise Repository Name |
-wsMANAGED_WORKSPACE=1 | Work in managed workspace mode |
-ws"PW_USER=<>" | ProjectWise User |
-ws"PW_PWD=<>" |
ProjectWise
Admin
If ProjectWise repository is specified and user/password are not specified then application will try to log-in in "Single-Sign-On/Windows Authentication" mode. |
-ws"AP_PROJID=<>" |
AutoPLANT Project ID
If this argument is specified, application will
connect to specified AutoPLANT project. Please do not specify following
argument:
|
-wsAP_PROJECTSROOT=<> |
AutoPLANT Project root
This optional but It is desirable to specify AutoPLANT project root with "-AP_PROJID". |
-wsAP_USER=<> | AutoPLANT Project User |
-wsAP_PASSWORD=<> |
AutoPLANT Project Password
User/Passwords are optional, but if not specified and user has not clicked "remember password" option in "AutoPLANT startup dialog", login dialog may popped up again. |
-wsSESSIONID=<> |
Session ID
Used to maintain unique session of application. For e.g. you cannot start multiple session of application in same project. But if you deliberately want to have multiple session with same project then pass SESSIONID. |
-wsRUN_FILE=<> |
Run file name
This argument can be consumed only by Isometric Processor. |
Run File Arguments
Argument | Description |
---|---|
PW_REPOSITORY | Name of ProjectWise repository |
MANAGED_WORKSPACE | Set to 1 to work in managed workspace mode. |
PW_USER |
ProjectWise user name If specified, PW_PWD will be compulsory. |
PW_PWD |
ProjectWise password If PW_USER/PWD not specified, it will be assumes "SINGLE SIGN ON" mode. |
ISOMETRIC_STYLE |
Style in which isometrics is to be generated. If this is not specified then, default isometric style, as configured in configuration manager, will be used. |
OPERATION |
This allows isometric generation in batch process from various sources. User can set operations as: IMODEL For each operation, there will separate set of arguments. You can specify only one type of operation per isometric session. |
IMODEL_DIRECTORY |
Defines directory where all i-models are stored. For this, OPERATION should defined as IMODEL. |
PW_IMODEL_DIRECTORY |
ProjectWise directory where all i-models are stored. For this OPERATION should be "IMODEL" |
Examples for Isometrics Manager Application
start %OutOPIM%Bentley\OpenPlantIsometricsManager\Bentley.Isometrics.App.exe -wpOPModeler_Imperial -ws"PW_USER=abc" -ws"PW_PWD=abc" -ws"PW_REPOSITORY=PlantQAServer4.bentley.com:op_824"
start %OutOPIM%Bentley\OpenPlantIsometricsManager\Bentley.Isometrics.App.exe -wpOPModeler_Imperial -ws"PW_REPOSITORY=PlantQAServer4.bentley.com:op_824"
start %OutOPIM%Bentley\OpenPlantIsometricsManager\Bentley.Isometrics.App.exe -wpOPModeler_Imperial
start %OutOPIM%Bentley\OpenPlantIsometricsManager\Bentley.Isometrics.App.exe -wpOPModeler_Imperial -ws"IMODEL_DIRECTORY=D:\Project\i-models\"
start %OutOPIM%Bentley\OpenPlantIsometricsManager\Bentley.Isometrics.App.exe -wpOPModeler_Imperial -ws"PW_USER=abc" -ws"PW_PWD=abc" -ws"PW_REPOSITORY=PlantQAServer4.bentley.com:op_824" -ws"PW_IMODEL_DIRECTORY=Project\i-models\"
start %OutOPIM%Bentley\OpenPlantIsometricsManager\Bentley.Isometrics.App.exe -wpOPModeler_Imperial -ws"PW_REPOSITORY= sameerp2k8:op262" -ws"MANAGED_WORKSPACE=1"
Examples for Isometric Processor
start %OutOPIM%Bentley\OpenPlantIsometricsManager\Bentley.Isometrics.Processor.exe -wpOPModeler_Imperial -wsRUN_FILE=%srcOPIM%RunFile.ini
OPERATION_TYPE=IMODEL #IMODEL ARGUEMENTS IMODEL_DIRECTORY=D:\Project\i-models\
PW_REPOSITORY=PlantQAServer4.bentley.com:op_824 MANAGED_WORKSPACE=0 PW_USER=abc PW_PWD=abc OPERATION_TYPE=IMODEL # IMODEL ARGUMENTS PW_IMODEL_DIRECTORY=Project\I-Models\
PW_REPOSITORY=PlantQAServer4.bentley.com:op_824 OPERATION_TYPE=IMODEL # IMODEL ARGUMENTS PW_IMODEL_DIRECTORY=Project\I-Models\