Dynamic Indexing of Report Entries
OpenPlant Isometrics Manager creates index attributes for various purpose like weld ID, cut ID, part ID, etc. You can use these index attributes in the reports to provide the link between graphics and report. You can also create dynamic index on the report order.
Following are the results of different combinations sorted
for Weld Reports:
- Sort= WELDNO.
report = weld2 indexprop = weldnum include = IE_TYPE = CT_WELD COLUMN = 5:C:weldnum COLUMN = 20:C:SIZE COLUMN = 20::TYPE SORT = WELDNO NODE = 61 end
- Sort = Type
report = weld2 indexprop = weldnum include = IE_TYPE = CT_WELD COLUMN = 5:C:weldnum COLUMN = 20:C:SIZE COLUMN = 20::TYPE SORT = TYPE NODE = 61 end
- Sort based on property
report = weld2 indexprop = weldnum include = IE_TYPE = CT_WELD COLUMN = 5:C:weldnum COLUMN = 20:C:SIZE COLUMN = 25:C:WELDNO COLUMN = 30:C:LENGTH COLUMN = 30::TYPE SORT = TYPE NODE = 61 end
- Sort based on weld type
Descending/Ascending by adding A/D.
report = weld2 indexprop = weldnum include = IE_TYPE = CT_WELD COLUMN = 5:C:weldnum COLUMN = 20:C:SIZE COLUMN = 25:C:WELDNO COLUMN = 30:C:LENGTH COLUMN = 30::TYPE SORT = TYPE:D NODE = 61 end
- The main report lists
both the field and shop welds. Field welds start at 500, shop welds at 550.
report = welds3 indexprop=weldnum:500 write = fieldwelds indexprop=weldnum:550 write = shopwelds NODE=61 end
report = fieldwelds include = IE_TYPE=CT_WELD && IE_FIELD=1 COLUMN = 5:C:weldnum COLUMN = 20:C:SIZE COLUMN = 20::TYPE SORT = weldnum end
report = shopwelds include = IE_TYPE=CT_WELD && IE_FIELD=0 COLUMN = 5:C:weldnum COLUMN = 20:C:SIZE COLUMN = 20::TYPE SORT = weldnum end