Copper Jumper
A Jumper feature is a (non-graphical) sheath that connects two splices together in a duct enclosure or in the same ped or vault. The Jumper command is normally used in ‘multi-sheath’ (non-graphical conduit) design. Though the ‘jumper’ is never displayed graphically, there is a logical connection made in the database. If graphic display of jumpers is desired, use the pigtail sheath.
- To Place a jumper, click on the jumper icon in the Placement section of the Copper tab:
- Locate the strand facility where the two devices are located that will be connected with the jumper. This will open the Jumper Information dialog box:
- Verify that the jumper ‘From and To’ equipment names are the correct ones to connect.
- Select the span type, the Cable ID, the pair range, status, length, and name of the jumper.
- Click OK to accept or Cancel to exit.