Upgrade Spec File
The Upgrade Spec File command creates a copy of an existing spec file with different design frequencies.
Upgrade a Spec File
- Select File > OpenComms Settings > Coax > Upgrade Spec File.
- The Upgrade Equipment File dialog box opens.
- Enter the new Equipment Spec file Name and select the Number of frequencies to be tracked.
- Enter the frequencies being used and select the appropriate boxes. Rvs – for reverse frequencies. Disp – for frequencies to be displayed.
- When completed, click Upgrade. After entering the new frequencies, the new equipment files are created, and changes can be entered.
- The new spec file can be opened by selecting Setup > Open Spec File and modifying the data for the frequencies that were changed.