Angle
|
Positive <angle value>
- Sets angle
between wye side branches.
|
Branch | Connection Length
|
Positive <numeric value>
- Sets length of
the un-threaded portion of a tee fitting. This is the distance between the main
branch centerline to where the threaded portion at EndSpec3 begins.
|
Branch | Connection Length (for
Branch Wye)
|
Positive <numeric value>
- Sets the straight
length at End3.
|
Branch Extension Length
|
Positive <numeric value>
- Sets the H branch
(End3) straight length between the bend and the start of the end condition,
that is parallel to the main branches (End1 and End2).
|
Branch Length
|
Positive <numeric value>
- Sets the straight
length for the angled portion of the heel (End3), ending at the bend start.
- Sets
the straight lengths for branches (at End2, and at End3) of Fire Dept
Connection.
|
Branch Outer Diameter
|
Positive <numeric value>
- Reduced branch
outside diameter of Fire Department Connection. Follows D3Ø .
|
Branch1 Outer Diameter
|
Positive <numeric value>
- Reduced branch
outside diameter.
|
Branch2 Outer Diameter
|
Positive <numeric value>
- Side branch
(End3) outside diameter.
|
Center to Branch Distance
|
Positive <numeric value>
- Sets distance
between main branch center line and End3 connect point.
|
Center to Inlet Distance
|
Positive <numeric value>
- Sets distance
between End1 connect point and End2 center line.
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
- Sets and sizes
end with a male connection.
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2;fe-.13 creates a flange at End1
with size 2, and a female connection at End2 with an overall reduction of
component's dimensions of .13
For Fire Department connection, the default
flange value to 0:6" (IP) & 12 mm (Metric).
|
Inlet | Straight Length
|
Positive <numeric value>
- Sets the straight
length of main of Fire Dept Connection at End1.
|
Inlet | Length
|
Positive <numeric value>
- Sets the offset
distance between the start of the un-threaded portion at EndSpec1 and the tee's
third branch center line at EndSpec3.
- Sets the straight
length at End1, (for Branch Wye).
|
Inlet to Branch Offset
|
Positive <numeric value>
- Sets the distance
between the End1 connect point and the End2 center line for trap fittings.
- Sets the distance
between the End1 connect point and the divergence point of the heel (End3)
center line.
|
Inlet | Outer Diameter
|
Positive <numeric value>
|
Outlet | Straight Length (for Fire
Dept Connection)
|
Positive <numeric value>
- Sets the straight
lengths of branches at End2, and End3.
|
Outlet | Length (for Branch Wye)
|
Positive <numeric value>
- Sets the straight
length at End2.
|
Outlet | Outer Diameter
|
Positive <numeric value>
- Outside diameter
of outlet branch of Fire Department Connection at end 2. Follows D1Ø.
|
Outlet to Branch Vertical Offset
|
Positive <numeric value>
- Sets the distance
between the main branch (End1/End2) and the heel (End3) center lines.
- Sets the distance
between the End1 center line and the trap center line.
|
Radius
|
Positive <numeric value>
- Sets center line
radii for wye/fire dept connection side branches.
|
Total Length
|
Positive <numeric value>
- Sets overall
length of fitting.
|