Cabinets
|
BMP_FireHoseCabinet "FireHoseCabinet"
|
Fire Hose Cabinet — Designed to
accommodate different combinations of fire hose racks.
|
BMP_FireHoseReelCabinet "FireHoseReelCabinet"
|
Hose Reel Cabinet — A single
door surface mounted Fire Hose Reel Cabinet designed to accommodate different
combinations of fixed and swinging hose reels fire hose reels.
|
BMP_LandingValveCabinet "LandingValveCabinet"
|
Landing Valve Cabinet — Fire
cabinet specially designed to store hydrant landing valves or other equipment.
|
BMP_ReelAndExtinguisherCabinet
"ReelAndExtinguisherCabinet"
|
Hose and Extinguisher Cabinet —
Vertical two-compartment Hose Reel and Extinguishers Cabinet designed to
accommodate a Hose Reel in upper compartment and the lower can house number of
fire extinguishers.
|
BMP_YardHydrantCabinet "YardHydrantCabinet"
|
Yard Hydrant Cabinet — Fire
cabinet suitable to house fire hoses, Jet spray nozzles, Dividing breeching
inlet, Fire axe, Crow bar and Hydrant wrench.
|
BMP_BreechingInletCabinet "RecessedType_2Way"
|
Breeching Inlet Cabinet –
Recessed Type, 2 Way — Breeching Inlet Cabinet is designed to accommodate 2-way
6" Outlet Breeching inlets, recesses mounting version.
|
BMP_BreechingInletCabinet "RecessedType_4Way"
|
Breeching Inlet Cabinet –
Recessed Type, 4 Way — Breeching Inlet Cabinet is designed to accommodate 4-way
4" Outlet Breeching inlets, recesses mounting version.
|
BMP_BreechingInletCabinet "SurfaceType_2Way"
|
Breeching Inlet Cabinet –
Surface Type, 2 Way — Breeching Inlet Cabinet is designed to accommodate 2-way
6" Outlet Breeching inlets, surface mounting version.
|
BMP_BreechingInletCabinet "SurfaceType_4Way"
|
Breeching Inlet Cabinet –
Surface Type, 4 Way — Breeching Inlet Cabinet to accommodate 4 nos 4" Outlet
Breeching inlets, surface mounting version.
|
BMP_FireExtinguisher "FireExtinguisher"
|
Fire Extinguisher — The fire
plug serving a source of water provided in most living areas with water
channeled into the tap. Used to combat fires by attaching a hose to the clapper
valves and opening.
|
BMP_FireHydrant "FireHydrant"
|
Fire Hydrant — Portable Fire
Extinguisher with pressure stored dry chemical, Carbon Dioxide
(CO2), water or Foam in the cylinder. Wall mountable.
|
FireDepartmentConnection Default
|
Fire Department Connection —
the out side fire department connection (FDC) is an important component found
on most sprinkler and standpipe systems, used for connecting hose lines from a
pumper truck when a sprinkler system activates.
|
Fire Protection Valves
|
BMP_AlarmCheckValve "Alarm Valve"
|
Alarm Check Valve — Designed
expressly for use in wet pipe (automatic sprinkler) fire protection systems.
The valve opens and allows pressurization of the alarm chamber upon the
operation of one or more automatic fire sprinklers.
|
BMP_BreechingInlet "BreechingInlet"
|
Breeching Inlet — A 2-way or
4-way breeching inlet set, installed in front of building accessible to fire
engine to feed water into riser systems via their fire hoses.
|
BMP_LandingValve "Type01"
|
Landing Valve — Simple valves
mounted in all the floor to install hydrant to provide water to extinguish fire
by connecting water hose to that valve.
|
BMP_LandingValve "Type02"
|
Landing Valve with Flange —
Landing valve with flange instead of screwed thread inherit comfort in
operation.
|
BMP_ZoneControlValve "Zone Valve"
|
Zone Valve — To control the
flow of saturated steam, hot water, and chilled water through coils and heat
exchanger of all types, in a wide range of HVAC applications.
|
BMP_HoseBibTap "Hose Bib"
|
Hose Bib Tap Type1 — A faucet
with a nozzle that is bent downward. A vertically oriented valve stem has its
bottom end detachably connected to the ball valve and its top end is connected
to a transversely extending lever handle.
|
BMP_HoseBibTap2 "Hose Bib"
|
Hose Bib Tap Type2 — Dripless
hose bib tap used in pressurized water source pipes. The screwed knob that
operates vacuum breaker to prevent backflow.
|
Sprinklers
|
BMP_SprinklerHead "SprinklerHead"
|
Sprinkler Head — Sprinkler is
the component of a fire sprinkler system that discharges water when the effects
of a fire have been detected, such as when a predetermined temperature has been
exceeded. Can set type Extended or Recessed and can have cap or no cap.
|
BMP_SprinklerHeadSideWall "SprinklerHeadSideWall"
|
Sprinkler Head Sidewall — Side
wall sprinkler heads stand out from a wall. They provide a half-circle spray
pattern. A second deflector also sprays water back toward the wall so that the
wall is protected. These are used when sprinklers cannot be located in the
ceiling.
|
BMP_SprinklerHeadUpright "SprinklerHeadUpright"
|
Sprinkler Head Upright —
Upright sprinkler heads project up into a space. They are generally used in
mechanical rooms or other inaccessible areas to provide better coverage between
obstructions. They also provide a circle spray pattern.
|