Body | Depth
|
|
Positive <numeric value>
- Sets depth of top
box of FCU.
|
Body | Length
|
|
Positive <numeric value>
- Sets length of
top box of FCU.
|
Body | Width
|
|
Positive <numeric value>
- Sets width of top
box of FCU.
|
Box | Depth
|
Box | Depth
|
Positive <numeric value>
- Sets the depth of
entire unit.
|
Box | Height
|
Box | Height
|
Positive <numeric value>
- Sets the height
of entire unit.
|
Box | Type
|
|
-
1-leftHanded
-
2-rightHanded
- Sets the side of
the control box on the unit.
Modifying this property maintains the location of the
inlets.
|
Box | Width
|
Box | Width
|
Positive <numeric value>
- Sets the width of
entire unit.
|
Cased
|
|
true
- Sets body casing
to the unit.
false
- Sets no casing to
the unit.
In Cased box, the coil and drain connections approximate
their length within Cased Offset.
|
Cased Offset
|
|
<numeric value>
- Sets offset to
all sides of casing from the unit, while
Cased is true.
|
Cell Library
|
|
<cell library file name>
- Library file name
for device cells.
|
Cell Symbol Name
|
|
<cell name>
- Sets the model
cell to the device.
Prerequisite of proper Cell Library for AHUs.
|
Center Side Offset
|
Center Side Offset
|
Positive <numeric value>
- Sets offset
distance between End1 connect point and side of box.
|
Center Top Offset
|
Center Top Offset
|
Positive <numeric value>
- Sets offset
distance between End1 connect point and top of box.
|
Coil | Length
|
Coil | Length
|
Positive <numeric value>
- Sets the straight
length of heating/cooling coils.
|
|
Coil | Outer Diameter
|
Positive <numeric value>
- Sets outside
diameter of coil connections.
|
|
Coil | Placement View
|
-
1-back
-
2-front
-
3-right
-
4-top
- Sets one of the
above sides of the control box to place coils.
|
Connection 1 | Length (L1)
|
|
Positive <numeric value>
- Sets straight length at End1.
- Sets connection length at End1.
|
Connection 2 | Length (L2)
|
|
Positive <numeric value>
- Sets straight length at End2.
- Sets connection length at End2.
|
Connection | End Type
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2;fe-.13 creates a flange at End1
with size 2, and a female connection at End2 with an overall reduction of
component's dimensions of .13
|
|
Connection Side
|
1-back
- Puts connection
End1 on back of the box/top box.
2-front
- Puts connection
End1 on front of the box/top box.
3-left
- Puts connection
End1 on left of the box/top box.
4-right
- Puts connection
End1 on right of the box/top box.
5-top
- Puts connection
End1 on top of the box/top box.
|
Connection Side Offset
|
Connection Side Offset
|
Positive <numeric value>
- Sets length of
straight portion at connection at END1.
|
Control | Depth
|
|
Positive <numeric value>
- Sets the depth of
the control box mounted on the unit.
|
Control | Length
|
|
Positive <numeric value>
- Sets the length
of the control box mounted on the unit.
|
Control | Offset Horizontal
|
|
Positive <numeric value>
- Sets offset to
control box from the side.
|
Control | Offset Vertical
|
|
Positive <numeric value>
- Sets offset to
control box from the top.
|
Control | Width
|
|
Positive <numeric value>
- Sets the width of
the control box mounted on the unit.
|
Cooling Coil Inlet |Side Offset
|
Cooling Coil Inlet | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to cooling coil inlet from the side.
|
Cooling Coil Inlet | Top Offset
|
Cooling Coil Inlet | Top Offset
|
Positive <numeric value>
- Sets vertical
offset to cooling coil inlet from the top.
|
Cooling Coil | Outer Diameter
|
|
Positive <numeric value>
- Sets outside
diameter of cooling coil connection.
|
Cooling Coil Outlet | Side Offset
|
Cooling Coil Outlet |Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to cooling coil outlet from the side.
|
Cooling Coil Outlet | Top Offset
|
Cooling Coil Outlet |Top Offset
|
Positive <numeric value>
- Sets vertical
offset to cooling coil outlet from the top.
|
Cooling Coil | Type
|
Cooling Coil | Type
|
-
0-none
-
1-plumbing
- 2-electrical (for
FCUs)
- Sets the type of
cooling coil.
Type plumbing adds provision for inlet/outlet of pipes.
The Heating Coil Type is always set opposite to
that of Cooling Coil Type. Both should not be none type, at least one type is
set plumbing, at least one type is set plumbing.
|
Drain Bottom Offset
|
Drain Bottom Offset
|
Positive <numeric value>
- Sets vertical
offset to drain outlet from the bottom.
|
Drain Location
|
|
1-Side
- Sets drain outlet
on tray at the side nearer to the box.
2-Front
- Sets drain outlet
on tray at the front side of the box.
3-Back
- Sets drain outlet
on tray at the back side of the box.
|
Drain | Outer Diameter
|
Drain | Outer Diameter
|
Positive <numeric value>
- Sets outside
diameter of drain connection.
|
Drain | Side Offset
|
Drain | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to drain outlet from the side.
|
Grille | Depth
|
Grille | Depth
|
Positive <numeric value>
- Sets depth of
grille portion.
|
Grille | Thickness
|
Grille | Thickness
|
Positive <numeric value>
|
Grille | Type
|
Grille | Type
|
2-bars
Sets default grille configuration to bars.
|
Grille | Width
|
Grille | Width
|
Positive <numeric value>
- Sets width of
grille portion.
|
Heating Coil Inlet | Side Offset
|
Heating Inlet Coil | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to heating coil inlet from the side.
|
Heating Coil Inlet | Top Offset
|
Heating Coil Inlet | Top Offset
|
Positive <numeric value>
- Sets vertical
offset to heating coil inlet from the top.
|
Heating Coil Outlet | Side Offset
|
Heating Coil Outlet | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to heating coil outlet from the side.
|
Heating Coil Outlet | Top Offset
|
Heating Coil Outlet | Top Offset
|
Positive <numeric value>
- Sets vertical
offset to heating coil outlet from the top.
|
Heating Coil | Outer Diameter
|
|
Positive <numeric value>
- Sets outside
diameter of heating coil connection.
|
Heating Coil | Type
|
Heating Coil | Type
|
-
0-none
-
1-plumbing
- 2-electrical (for
FCUs)
- Sets the type of
heating coil.
Type plumbing adds provision for inlet/outlet of pipes.
The Cooling Coil Type is always set opposite to
that of Heating Coil Type. Both should not be none type, at least one type is
set plumbing.
|
Main Connection Offset Horizontal
|
|
Positive <numeric value>
- Sets offset
distance between End1 connect point and side of box.
|
Main Connection Offset Vertical
|
|
Positive <numeric value>
- Sets offset
distance between End1 connect point and top of box.
|
|
Opening Length
|
Positive <numeric value>
- Sets length of
the grille opening on the panel.
|
Opening Width
|
Opening Width
|
Positive <numeric value>
- Sets length of
the grille opening on the panel.
|
Orientation
|
|
Sets orientation of the unit.
1-Horizontal
- Horizontal
orientation sets connections on front/back sides, along the length of the box.
2-Vertical
- Vertical
orientation sets connections on left/right sides, along the depth of the box.
|
|
Panel Length
|
Positive <numeric value>
- Sets length of
the panel the unit is mounted.
|
Panel Width
|
Panel Width
|
Positive <numeric value>
- Sets width of the
panel the unit is mounted.
|
Run Connection Offset Horizontal
|
|
Positive <numeric value>
- Sets offset
distance between End2 connect point and side of box.
|
Run Connection Offset Vertical
|
|
Positive <numeric value>
- Sets offset
distance between End2 connect point and top of box.
|
Tag
|
Tag
|
<alpha-numeric characters>
- Sets tag value
visible in output of drawing composition in dynamic view.
Separate tag strings with a semi colon
|
|
Top Box Depth
|
Positive <numeric value>
- Sets depth of top
box of beam.
|
|
Top Box Height
|
Positive <numeric value>
- Sets height of
top box of beam.
|
|
Top Box Width
|
Positive <numeric value>
- Sets width of top
box of beam.
|
Tray Bottom Offset
|
|
<numeric value>
- Sets offset to
tray from bottom side.
|
Tray Extension
|
|
Positive <numeric value>
- Sets extent to
the drain tray within Cased Offset.
|
Tray Height
|
|
Positive <numeric value>
- Sets height of
the drain tray.
|
Tray Width
|
|
Positive <numeric value>
- Sets width of the
drain tray.
|
With Control Box
|
|
true
- Sets control box
on the side of the unit as set in Box Type.
false
- Sets no control
box on the unit.
|