Angle
|
Angles less than or equal to 90°
- Sets the angle
between tap pipe End1 and nose End2 of a hose bib.
|
Blade Angle
|
Angles less than or equal to 90°
- Sets the rotation
(in the plane perpendicular to the valve outlets) of the valve's internal flow
obstruction.
|
Blade Depth
|
Positive <numeric value>
- Sets the
thickness of the valve's internal flow obstruction.
|
Blade Diameter
|
Positive <numeric value>
- Sets the diameter
of the valve's internal flow obstruction.
The value is limited by the overall diameter of the valve
body.
|
Body | Depth
|
Positive <numeric value>
- Sets depth of
valve body.
|
Body | Diameter
|
Positive <numeric value>
- Sets cylinder
diameter for main body of valve.
Note: For ports on valve body, e.g. in Alarm Check
value, the port diameters D1-D4 are always set less than the body diameter.
|
Body | Length
Total Length
|
Positive <numeric value>
- Sets the
horizontal length of valve fitting.
- Sets pipe length
from End1 connect point to valve center.
|
Body | Outer Diameter
|
Positive <numeric value>
- Sets outside
diameter for Vent body.
|
Body Type
|
- Defines the shape
of the upper body of the valve.
|
Body | Width
|
Positive <numeric value>
- Sets the width of
valve unit.
|
Bypass Height
|
Positive <numeric value>
- Sets distance
between the bypass center lines at End1 and at End3.
|
Cap Base | Diameter
|
Positive <numeric value>
- Sets outside
diameter for base of cap on the valve bonnet.
|
Cap Base | Length
|
Positive <numeric value>
- Sets length of
cap on the valve bonnet.
|
Cap Body | Diameter
|
Positive <numeric value>
- Sets diameter of
cap placed on the top of valve.
|
Cap Body | Length
|
Positive <numeric value>
- Sets length of
cap around the pressure adjusting screw on the valve top.
|
Cap Diameter
|
Positive <numeric value>
- Sets outside
diameter for cap on the body of air vent.
|
Cap | Length
|
Positive <numeric value>
- Indicates the
preset value for the lengths of the cap, included in
Outlet to Top Distance
.
|
Cap | Width
|
Positive <numeric value>
- Sets the width of
the Cap assembly.
|
Cell Library
|
<cell library file name>
- Library file name
for device cells.
|
Cell Symbol Name
|
<cell name>
- Sets the model
cell to the device.
Prerequisite of proper Cell Library for AHUs.
|
Center to Connection 1 Distance
Inlet to Center Distance
|
Positive <numeric value>
- Sets distance
between End1 and valve center.
|
Center to Connection 2 Distance
Outlet to Center Distance
|
Positive <numeric value>
- Sets distance
between End2 and valve center.
|
Center to Connection 3 Distance
|
Positive <numeric value>
- Sets distance
between End3 and valve center.
|
Center to Connection 4 Distance
|
Positive <numeric value>
- Sets distance
between End4 and valve center.
|
Center to Outlet Distance
|
Positive <numeric value>
- Sets the length
between valve axis to the End2 (outlet).
|
Coil | Diameter
|
Positive <numeric value>
- Sets diameters to
coil connections (D3–D5) on the branch of valve and cap body.
|
Coil | Length
|
Positive <numeric value>
- Sets length of
coil connections (D3–D5).
|
Configuration
|
-
1-Flow Configuration
-
2-Return Configuration
- Sets DPDC valve
configuration to work in flow or return pipework .
|
Connection 1 | Length (L1)
Connection 3 | Length (L3)
Connection 3 | Length (L3)
Connection 4 | Length (L4)
|
Positive <numeric value>
- Sets the straight
length at End1, End2, End3, and End4, respectively
|
Plumbing Connection 1 | Outer
Diameter
Plumbing Connection 2 | Outer Diameter
Plumbing Connection 3 |Outer Diameter
Plumbing Connection 4 |Outer Diameter
|
Positive <numeric value>
- Sets pipe outside
diameter for
- End1
- End2
- End3 and
- End4, respectively.
|
Plumbing Connection | Outer
Diameter
Inlet Outer Diameter
|
Positive <numeric value>
- Sets the outside
dimension of the valve main.
- Sets pipe outside
diameters for End1. Same for End2, Nose Outer Diameter.
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
- Sets and sizes
end with a male connection.
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2;fe-.13 creates a flange at End1
with size 2, and a female connection at End2 with an overall reduction of
component's dimensions of .13
|
Connection | Type
|
- 1-SideInlet
SideOutlet – Ends side-by-side horizontally opposite.
- 2-SideInlet
BottomOutlet – End2 at the base end.
- Determines the
positions of the End2 of (Straight Relief) valve.
|
Depth
|
Positive <numeric value>
- Sets the width of
the valve body/bonnet. Sets depth of switch assembly, in case of flow switch.
|
Diameter
Valve Body Diameter
|
Positive <numeric value>
- Sets the diameter
of the valve body/bonnet.
|
Diaphragm Depth
|
Positive <numeric value>
- Sets the depth of
the diaphragm assembly of pressure transducer.
|
Flange Size
|
Positive <numeric value>
- Sets the flange
dimension, exterior to reducer body at both sides of check valve.
|
Flange | Thickness
Motor | Flange Thickness
|
Positive <numeric value>
- Sets the
thickness to the flanges attached to both sides of check valve body.
|
Handle Diameter
|
Positive <numeric value>
- Sets diameter of
handwheel that controls valve operation.
|
Height
|
Positive <numeric value>
- Sets vertical
distance between the main branch center line and the side branch.
|
Hose | Diameter
|
Positive <numeric value>
- Sets hose branch
outside diameter for End2.
|
Hose | Length
|
Positive <numeric value>
- Sets hose pipe
length along main pipe, equal to tangential distance between hose contact and
the end of hose pipe at End2.
|
Horizontal Pipe | Length
|
Positive <numeric value>
- Sets main pipe
length between End2 and End3 connect points. Cannot be smaller than D1 .
|
Horizontal Pipe | Outer Diameter
|
Positive <numeric value>
- Sets horizontal
pipe outside diameters for End2 and End3. Equal or less than D1.
|
Inlet | Length
|
Positive <numeric value>
- Sets the straight
length at End1.
|
Inlet to Outlet Distance
Connection Height
|
Positive <numeric value>
- AngledRelief -
Sets the height between the center of End2 and End1 (inlet).
-
PilotRelief/PressureRegulating/StraightRelief - Sets the height between the
center of End1 and the base.
|
Length
Total Length
|
Positve <numeric value>
- Sets the overall
length of the valve body/bonnet including flange thickness, if any.
|
Lever Height
|
Positive <numeric value>
- Sets height of
the lever attached on the top of branch; equal to distance between End1 center
line and the top of the branch.
|
Lever Length
Lever Width
|
Positive <numeric value>
- Sets height and
width of the lever shaft attached on the top of branch.
|
Nose Length
|
Positive <numeric value>
- Sets nose length
of branch pipe from End2 connect point.
|
Nose Outer Diameter
|
Positive <numeric value>
- Sets nose branch
outside diameter for End2. Same as Connection Outer Diameter at
End1.
|
Number of Ports
|
<integer>
between 1 and 4.
- Sets number of
ports to the valve; e.g. Alarm Check valve can have 2-4 ports.
Their sides and offset can also be managed using the Port
Location and Offset properties.
|
Operator Offset
|
Positive <numeric value>
- Sets the offset
of actuating shaft towards End2.
|
Outlet | Length
|
Positive <numeric value>
- Sets the straight
length at End2.
|
Outlet to Top Distance
|
Positive <numeric value>
- AngledRelief -
Sets the height between the center of End2 and the adjusting bolt.
-
PilotRelief/PressureRegulating/StraightRelief - Sets height between the center
of End1 and the outer surface of the cap of the adjusting bolt.
|
Options
|
-
1-Screw
-
2-With Cap
-
3-Pilot
- Defines the
option for the top assembly of (pressure regulating) valve.
|
Plate Diameter
|
Positive <numeric value>
- Sets outer
diameter of cylindrical housing of capacitance plates, used to sense diaphragm
positioning and convert the differential pressure into electrical signal.
|
Plate Length
|
Positive <numeric value>
- Sets straight
length of cylindrical assembly of plates mounted between diaphragm and
transmitter of DP Transmitter.
|
Port Location
|
Sides <left |
right>
- Sets the location
of ports; either to left or right. The location is set using the sequence of
string, each separated with ";", e.g. for 3 ports it could be
"Left;Right;Right" meaning, the 1st port in the left and
port numbers 2 and 3 in the right.
|
Port Offset
|
Positive <numeric
values>
- Sets horizontal
offset between two adjacent ports; minimum 0.5 inch. The offset values are set
using the sequence of numeric values, each separated with ";", e.g. for 3 ports
it could be "0.5;0.5;2" meaning, the 1st port in the
left is offset 0.5, and port numbers 2 and 3 in the right are with 0.5, and
2.0.
Useful where non collinear ports need to be set.
|
Reducer Diameter
|
Positive <numeric value>
- Sets diameters of
reduce openings of flow/system at both sides of valve.
|
Reducer Length
|
Positive <numeric value>
- Sets the distance
between the reduce opening and valve body it is attached.
|
Relief Valve Type
|
1-Piston Type
- Sets the valve in
a cylindrical body structure. It limits a specific pump discharge pressure on
machine tool hydraulic systems, oil burning equipment, rams, presses, lifts,
etc.
2-Direct Acting
- Sets the type to
angle-type suitable to low to moderate flows.
|
Stem Diameter
|
Positive <numeric value>
- Sets diameter of
branched stem under the cap of differential valve. Follows main diameters at
End1/End2.
|
Stem Height
|
Positive <numeric value>
- Sets straight
length of branch elevated from center line of End1 main pipe .
|
Stem Offset
Branch | Offset
|
Positive <numeric value>
- Sets distance of
side branch center from End1 on main pipe.
|
Switch Type
|
1-Paddle
- Default type set
for flow switch type Paddle valve.
2-Vane
- Default type set
for flow switch type Vane valve.
|
Tag
|
<alpha-numeric characters>
- Sets tag value
visible in output of drawing composition in dynamic view.
Separate tag strings with a semi colon
|
Thickness
|
Positive <numeric value>
- Sets the valve
body's wall thickness.
|
Total Length
|
Positive <numeric value>
- Sets the distance
between End1 and End2 of valve.
|
Transmitter Diameter
|
Positive <numeric value>
- Sets outer
diameter of cylindrical housing of transmitter placed on top of valve.
|
Transmitter Length
|
Positive <numeric value>
- Sets straight
length of transmitter assembly mounted on top of valve.
|
U- Bolt Size
|
Positive <numeric value>
- Sets straight
distance between two ends of U-bolt.
|
Valve Body Height
|
Positive <numeric value>
- Sets the valve
unit height from the base.
|
Valve Operator Parameters
|
Name=<type of operator>,A=<numeric
value>,B=<numeric value>,C=<numeric value>,Primary=<angle
value>,Tertiary=<angle value>,Secondary=<angle
value>
-
Name:Sets operator type to either
Handwheel, Wrench, Electrical or Gear.
-
A:-Sets the handwheel's
diameter.-Sets the electrical box's larger size dimension. -Sets the vertical
offset distance between the valve axis and the wrench. -Sets the vertical
offset distance between the valve axis the gear box's centerline.
-
B:-Sets the offset distance between
the valve and the handwheel. -Sets the offset distance between the valve and
the outermost surface of the electrical box. -Sets the horizontal offset
distance between the valve axis and the end of wrench.-Sets the distance
between the gear box's centerline to the end of the gear actuation shaft.
-
C:-Sets the handwheel actuator shaft
diameter. -Sets the electrical actuator shaft diameter.-Sets the gear operator
hand control diameter.
-
D:-Sets the horizontal offset
distance between the valve axis and the hand control.
-
E:-Sets the horizontal offset
distance between the gear actuator shaft and the hand control axis.
-
Primary:Sets rotation of operator
along the valve axis in degrees.
-
Secondary:Sets the orientation of
the operator relative to operator's shaft axis.
-
Tertiary:Sets rotation of operator
perpendicular to the valve axis in degrees. Positive values rotate the operator
towards End2 and negative values rotate the operator towards End1.
|
Valve Type
|
1-ball
2-globe
- Sets valve type
to globe.
3-gate
4-plug
5-other
- Sets valve type
to other.
|
Vertical Pipe | Length
|
Positive <numeric value>
- Sets vertical
pipe length from End1 connect point. Cannot be smaller than
Horizontal Pipe Outer Diameter. .
|
Vertical Pipe | Outer Diameter
|
Positive <numeric value>
- Sets vertical
pipe outside diameter for End1 (D1).
|
Width
|
Positive <numeric value>
- Sets width of
switch assembly.
|
Wrench Length
|
Positive <numeric value>
- Sets length of