Body | Depth |
Positive <numeric value>
- Sets the depth of entire unit.
|
Body | Length |
Positive <numeric value>
|
Body | Width |
Positive <numeric value>
- Sets the width of entire unit.
|
Cell Library |
<cell library file name>
- Library file name for device cells.
|
Cell Symbol Name |
<cell name>
- Sets the model cell to the device.
Prerequisite of proper Cell Library for AHUs. |
Coil | Offset |
Positive <numeric value>
- Sets distance between the two coil connections. Limited by device body dimension properties.
|
Coil Connection | Side |
-
1-back
-
2-front
-
3-top
-
4-bottom
- Sets the location or surface on the unit for coil connections.
|
Coil Connection | Outer Diameter |
Positive <numeric value>
- Sets outside diameter of coil connections.
|
Coil Connection | Offset |
Positive <numeric value>
- Sets an offset distance between coil connections and back of device.
|
Coil | Type |
-
0-none
-
1-plumbing
-
2-electrical
|
Connection 1 | Length (L1) |
Positive <numeric value>
- Sets straight length at End1.
- Sets connection length at End1.
|
Connection 2 | Length (L2) |
Positive <numeric value>
- Sets straight length at End2.
- Sets connection length at End2.
|
Connection 3 | Length (L3) |
Positive <numeric value>
- Sets straight length at End3.
Adds to the Body Length property.
|
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Control | Connection Side |
-
1-back
-
2-front
-
3-top
-
4-bottom
- Sets the location or surface on which the device control box is located.
|
Control | Depth |
Positive <numeric value>
- Sets the depth of the control box mounted on the unit.
|
Control1 | Depth |
Positive <numeric value>
- Sets the depth of the first control box mounted on a dual inlet device.
|
Control2 | Depth |
Positive <numeric value>
|
Control | Length |
Positive <numeric value>
- Sets the length of the control box mounted on the unit.
|
Control1 | Length |
Positive <numeric value>
- Sets the length of the first control box mounted on a dual inlet device.
|
Control2 | Length |
Positive <numeric value>
- Sets the length of the second control box mounted on a dual inlet device.
|
Control | Offset |
<numeric value>
- Sets an offset distance between the front surfaces of the control box and the device body.
|
Control1 Offset |
<numeric value>
- Sets an offset distance between the front surfaces of the first control box and the device body.
|
Control2 | Offset |
<numeric value>
- Sets an offset distance between the front surfaces of the second control box and the device body.
|
Control | Side Distance |
Positive <numeric value>
- Sets the offset distance between the bottom of the control box and the bottom of the device on which it is mounted.
|
Control | Width |
Positive <numeric value>
- Sets the width of the control box mounted on the unit.
|
Control1 Width |
Positive <numeric value>
- Sets the width of the first control box mounted on a dual inlet device.
|
Control2 Width |
Positive <numeric value>
- Sets the width of the second control box mounted on a dual inlet device.
|
Electrical Extension |
Positive <numeric value>
- Sets length of electrical connection box.
Note: Coil Type property must be set to <2–electrical>.
|
Induction Bottom Distance |
Positive <numeric value>
- Sets offset distance between the bottom of induction opening and the bottom of device box. Limited by body dimensional properties.
|
Induction Depth |
Positive <numeric value>
- Sets induction opening depth. Limited by body dimensional properties.
|
Induction Length |
Positive <numeric value>
- Sets induction opening length.
|
Induction Side Distance |
Positive <numeric value>
- Sets offset distance between the side of induction opening and the side of device box. Limited by body dimensional properties.
|
Induction Width |
Positive <numeric value>
- Sets induction opening width. Limited by body dimensional properties.
|
Inlet | Bottom Distance |
Positive <numeric value>
- Sets offset distance between the bottom of End1 and the bottom of device box. Limited by body dimensional properties.
|
Inlet | Offset |
Positive <numeric value>
- Sets offset distance between the inlets on a dual inlet device.
Limited by the sum of the inlet radii and the size of the device enclosure. |
Inlet | Side Distance |
Positive <numeric value>
- Sets offset distance between the side of End1 and the side of device box. Limited by body dimensional properties.
|
Outlet Bottom Distance |
Positive <numeric value>
- Sets offset distance between the bottom of End2 and the bottom of device box. Limited by body dimensional properties.
|
Outlet | Side Distance |
Positive <numeric value>
- Sets offset distance between the side of End2 and the side of device box. Limited by body dimensional properties.
|
Replaced Cell Tag |
<tag>;<tag>;<tag>;<tag>
- Sets tags displayed in drawing output.
This property is set to un-editable by default. |
Side Distance |
Positive <numeric value>
- Sets the offset distance between the device enclosure's front side and the center line of the first inlet (End1).
|
Tag |
<alpha-numeric characters>
- Sets tag value visible in output of drawing composition in dynamic view. Separate tag strings with a semi colon
|
VAV Box Type |
-
1-leftHanded
-
2-rightHanded
- Sets the side of the control box on the unit.
By default, set hidden by in catalog Editor. Modifying this property maintains the location of the inlets.
|