Base Diameter |
Positive <numeric value>
- Sets base diameter of fire hydrant.
|
Body | Depth |
Positive <numeric value>
- Sets depth of fire equipment, that is height for cabinet.
|
Body | Diameter |
Positive <numeric value>
- Sets diameter of fire extinguisher body.
|
Body | Height |
Positive <numeric value>
- Sets height of valve/cabinet.
|
Body | Length |
Positive <numeric value>
- Sets fire length of valve/cabinet. Height, in case of fire hydrant/extinguisher.
|
Body | Width |
Positive <numeric value>
- Sets width for fire cabinet, breeching inlet.
|
Base Stand Height |
Positive <numeric value>
- Sets height to bottom stand of floor mounted fire cabinets such as firehose and yard hydrant cabinets.
|
Breeching Inlet Type |
-
SurfaceType-2-Way
-
SurfaceType-4-Way
-
RecessedType-2-Way
-
RecessedType-4-Way
- Sets breeching inlet construction for type of Breeching Inlet Cabinets.
|
Cell Library |
<cell library file name>
- Library file name for device cells. For example, Vessel01.
|
Cell Symbol Name |
<cell name>;scale=<numeric value>
- Sets the model cell displayed to the device.
- Scale entry fits cell proportionally to extents of device.
|
Connection End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Connection | Side |
- Sets the location on the fire cabinet side for the connection.
|
Extinguisher Type |
-
1-Dry Chemical
-
2-CO
2
-
3-Water
-
4-Foam
- Sets type fire fighting agent used for a stored pressure or cartridge-operated extinguisher.
- Dry chemical, CO2 expellant gas type belong to class ABC, and Water, Foam in class BC type.
|
Connection | Length Connection 1 | Length (L1)
Inlet | Length |
<numeric value>
- Sets length of male or female connection for End1. Set End Type to male or female to see change in geometry. If End Type is flange, the connection point moves.
|
Inlet Type |
- Sets number of inlet ports; 2 in case of 2-way and 4 in case of 4-way breeching inlet type.
|
Inlet | Outer Diameter |
Positive <numeric value>
- Sets outer diameter of fire hydrant pipe.
- Defines material property in case of Breeching Inlet.
|
Outer Frame Size |
Positive <numeric value>
- Sets frame size of guard panel extending beyond body length and depth of Recessed type Breeching Inlet cabinets.
|
Port Diameter |
Positive <numeric value>
- Sets diameter of both inlet ports in 2-Way and all 4 in 4-Way type.
|
Port Length |
Positive <numeric value>
- Sets length of both inlet ports in 2-Way and all 4 in 4-Way type.
|
Tag |
<alpha-numeric characters>
- Sets tag value visible in output of drawing composition in dynamic view.
- Example; abbreviated tags to fire equipment like FHC for fire host cabinet, FH for fire hydrant, ST_2 for Surface Type Breeching Inlet etc., can be set.
|
Valve Operator Param
|
Name=<type of operator>,A=<numeric value>,B=<numeric value>,C=<numeric value>,Primary=<angle value>,Tertiary=<angle value>,Secondary=<angle value>
- Name:Sets operator type to either Handwheel, Wrench, Electrical or Gear.
- A:-Sets the handwheel's diameter.-Sets the electrical box's larger size dimension. -Sets the vertical offset distance between the valve axis and the wrench. -Sets the vertical offset distance between the valve axis the gear box's centerline.
- B:-Sets the offset distance between the valve and the handwheel. -Sets the offset distance between the valve and the outermost surface of the electrical box. -Sets the horizontal offset distance between the valve axis and the end of wrench.-Sets the distance between the gear box's centerline to the end of the gear actuation shaft.
- C:-Sets the handwheel actuator shaft diameter. -Sets the electrical actuator shaft diameter.-Sets the gear operator hand control diameter.
- D:-Sets the horizontal offset distance between the valve axis and the hand control.
- E:-Sets the horizontal offset distance between the gear actuator shaft and the hand control axis.
- Primary:Sets rotation of operator along the valve axis in degrees.
- Secondary:Sets the orientation of the operator relative to operator's shaft axis.
- Tertiary:Sets rotation of operator perpendicular to the valve axis in degrees. Positive values rotate the operator towards End2 and negative values rotate the operator towards End1.
|