Box | Depth
|
Positive <numeric value>
- Sets depth of box
containing the measuring equipment (e.g. Gas Meter).
|
Box | Height
|
Positive <numeric value>
- Sets height of
box containing the measuring equipment.
|
Box | Length
|
Positive <numeric value>
- Sets length of
box containing the measuring equipment (e.g. Gas Relay).
|
Box | Width
|
Positive <numeric value>
- Sets width of box
containing the measuring equipment.
|
Connection 1 | Length (L1)
|
Positive <numeric value>
- Sets the straight
length at End1.
|
Connection 2 | Length (L2)
|
Positive <numeric value>
- Sets the straight
length at End2.
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
- Sets and sizes
end with a male connection.
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2;fe-.13 creates a flange at End1
with size 2, and a female connection at End2 with an overall reduction of
component's dimensions of .13
|
Depth
|
Positive <numeric value>
- Sets depth of
vibrator pad.
|
Frame | Height
|
Positive <numeric value>
- Sets length of
the thermometer body.
|
Frame | Thickness
|
Positive <numeric value>
- Sets depth of the
thermometer body.
|
Frame | Width
|
Positive <numeric value>
- Sets width of the
thermometer body.
|
Gauge Body Diameter
|
Positive <numeric value>
- Sets outside
diameter for body of gauge.
Typically greater than (2 x D1Ø ). Where D1 is
the diameter of the main body, at End1.
|
Gauge Diameter
|
Positive <numeric value>
- Sets outside
diameter for gauge dial.
|
Gauge Thickness
|
Positive <numeric value>
- Sets depth for
body of gauge.
|
Inlet | Length
|
Positive <numeric value>
- Sets distance
between End1 and the gauge body.
|
Plumbing Connection | Outer Diameter
|
Positive <numeric value>
- Sets outside
diameter for End1.
|
Length
|
Positive <numeric value>
- Sets length of
vibrator pad.
|
Number Of Slabs
|
Positive <integer>
- Sets number of
slabs on pad.
|
Outlet | Bottom Offset
|
Positive <numeric value>
- Sets vertical
offset between center of inlet connection at End1 and bottom of box of
measuring equipment.
|
Slabs Thickness
|
Positive <numeric value>
- Sets suitable
thickness internally to the slabs placed on vibration pad.
|
Tag
|
<alpha-numeric characters>
- Sets tag value
visible in output of drawing composition in dynamic view.
Separate tag strings with a semi colon
|
Width
|
Positive <numeric value>
- Sets width of
vibrator pad.
|