Access Panel Depth
|
Positive <numeric value>
- Sets thickness of
guard panel attached along side of vessel.
|
Access Panel Length
|
Positive <numeric value>
- Sets length of
guard panel attached along side of vessel.
|
Access Panel Width
|
Positive <numeric value>
- Sets width of
guard panel attached along side of vessel.
|
Air Intake Bottom Offset
|
Positive <numeric value>
- Sets the offset
between Air Intake connection at End1 and the bottom of equipment.
|
Air Intake Connection Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Air Intake
connection on one of the above sides of equipment box.
|
Air Intake Diameter
|
Positive <numeric value>
- Sets outside
diameter of Air Intake connection of equipment (e.g. Boiler).
|
Air Intake Side Offset
|
Positive <numeric value>
- Sets offset
between Air Intake connection and side of equipment.
|
Bar Thickness
|
Positive <numeric value>
- Sets default
thickness of the bars forming grille surface on the equipment (e.g. Catch
Basin).
|
Base
|
- Sets or no base
at the bottom of vessel (e.g. Air Separator).
|
Base | Height
|
Positive <numeric value>
- Sets height of
the base attached to vessel bottom. Disabled when No Base is set.
|
Base Inside
|
Positive <numeric value>
- Sets distance
between the two bars of base of boiler.
|
Base Length
|
Positive <numeric value>
- Sets length of
base bars, initially matching the length of the boiler.
|
Base To Bottom Of Boiler
|
Positive <numeric value>
- Sets distance
between base and the bottom of the boiler tube.
|
Body | Height
|
Positive <numeric value>
- Sets height of
the body, including control box.
|
Body Length
|
Positive <numeric value>
- Sets length of
the equipment body.
|
Body Width
|
Positive <numeric value>
- Sets depth of the
equipment body.
|
Boiler Rating
|
Positive <numeric value>
- Sets rating of
boiler in Btu/Hr in Imperial and kW in Metric unit system.
|
Boiler Type
|
-
1-RIRETUBE– for Fire Tube type
boiler equipment.
-
2-WATERTUBE– for Water Tube type
boiler equipment.
- Sets respective
boiler types.
|
Bottom Offset (Outlet)
|
Positive <numeric value>
- Sets offset
distance between End1 connect point and bottom of equipment.
|
Bottom Offset Outlet1
|
Positive <numeric value>
- Sets vertical
offset to Outlet1 connection at End2 from the bottom.
|
Bottom Offset Outlet2
|
Positive <numeric value>
- Sets vertical
offset to Outlet2 connection at End3 from the bottom.
|
Box | Height
Box | Length
Box | Width
|
Positive <numeric value>
- Sets dimensions
of sides of equipment box.
|
Brackets Length
Brackets Thickness
Brackets Width
|
Positive <numeric value>
|
Cell Library
|
<cell library file name>
- Library file name
for device cells.
For example, Vessel01.
|
Cell Symbol Name
|
<cell name>;scale=<numeric
value>
- Sets the model
cell displayed to the device.
- Scale entry fits
cell proportionally to extents of device.
|
Chilled Water In | Bottom Offset
|
Positive <numeric value>
- Sets the offset
between Chilled Water IN connection at End1 and the bottom of the Chiller unit.
|
Chilled Water In | Connection Side
|
- Puts the Chilled
Water IN connection at End1 on one of the above sides of Chiller box.
|
Chilled Water In | Diameter
|
Positive <numeric value>
- Sets outside
diameter of Chilled Water IN connection at End1.
|
Chilled Water In | Side Offset
|
Positive <numeric value>
- Sets the offset
between Chilled Water IN connection at End1 and the side of the Chiller unit.
|
Chilled Water Out | Bottom Offset
|
Positive <numeric value>
- Sets the offset
between Chilled Water OUT connection at End2 and the bottom of the Chiller
unit.
|
Chilled Water Out | Connection Side
|
- Puts the Chilled
Water OUT connection at End2 on one of the above sides of Chiller box.
|
Chilled Water out | Diameter
|
Positive <numeric value>
- Sets outside
diameter of Chilled Water OUT connection at End2.
|
Chilled Water Out | Side Offset
|
Positive <numeric value>
- Sets the offset
between Chilled Water OUT connection at End2 and the side of the Chiller unit.
|
Coil Length
|
Positive <numeric value>
- Sets the straight
length of (3)coils at Ends.
|
Cold Water Pipe | Length
|
Positive <numeric value>
- Sets distance
between End1 and the vessel body.
|
Cold Water Pipe | Outer Diameter
|
<numeric value>
- Sets pipe outside
diameter for End1 of water heater.
|
Condenser Type
|
-
1-Type01
-
2-Type02
-
3-Type03
- Sets condenser
type.
- Determines number
of compressors; 1 compressor for Type01 and Type02 and 2 for Type03.
Type determines fan and grille positions.
- Type01: Fan at Side | Grille to Left
- Type02: Fan at Top| Grille to Front
- Type03: 2 Fans at Top| Grille to Front
|
Condenser Water IN Bottom Offset
|
Positive <numeric value>
- Sets the offset
between Chilled Water IN connection at End5 and the bottom of the Chiller unit.
|
Condenser Water IN Connection Side
|
- Puts the
Condenser Water IN connection at End5 on one of the above sides of Chiller box.
|
Condenser Water IN Diameter
|
Positive <numeric value>
- Sets outside
diameter of Chilled Water IN connection at End5.
|
Condenser Water IN Side Offset
|
Positive <numeric value>
- Sets the offset
between Chilled Water IN connection at End5 and the side of the Chiller unit.
|
Condenser Water OUT Bottom Offset
|
Positive <numeric value>
- Sets the offset
between Chilled Water OUT connection at End6 and the bottom of the Chiller
unit.
|
Condenser Water OUT Connection Side
|
- Puts the
Condenser Water OUT connection at End6 on one of the above sides of Chiller
box.
|
Condenser Water OUT | Diameter
|
Positive <numeric value>
- Sets outside
diameter of Chilled Water OUT connection at End6.
|
Condenser Water OUT | Side Offset
|
Positive <numeric value>
- Sets the offset
between Chilled Water OUT connection at End6 and the side of the Chiller unit.
|
Connection 1 | Length
(L1)
Connection 2 | Length (L2)
Connection 3 | Length (L3)
Connection 4 | Length (L4)
Connection 5 | Length (L5)
Connection 6 | Length (L6)
|
Positive <numeric value>
- Sets the straight
length at:
- End1
- End2
- End3
- End4
- End5
- End6, respectively.
|
Connection1 Outer
Diameter
Connection2 Outer Diameter
Connection3 Outer Diameter
|
Positive <numeric value>
- Sets pipe outside
diameters for:
- End1
- End2
- End3, respectively.
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
- Sets and sizes
end with a male connection.
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2;fe-.13 creates a flange at End1
with size 2, and a female connection at End2 with an overall reduction of
component's dimensions of .13
|
Connection | Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
- Puts connection
on one of the above sides of condenser box.
|
Connection Type
|
1 - Single Phase
- Sets the electric
connection type of boiler to single phase capacity.
2 - 3 Phase
- Sets the electric
connection type of boiler to 3 Phase capacity.
|
Control Box Height
|
Positive <numeric value>
- Sets height of
the control box. Equals 1/10th of Body Height.
|
Control Connection Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top– exception Chillers.
- Puts control
connection on one of the above sides of equipment box.
|
Control Height
Control Length
Control Width
|
Positive <numeric value>
- Sets dimensions
of sides of control (box) placed on the equipment side.
|
Control Side Offset
|
Positive <numeric value>
- Sets offset
between control box assembly and side of equipment.
|
Control Top Offset
|
Positive <numeric value>
- Sets offset
between control box assembly and top of equipment.
|
Depth
|
Positive <numeric value>
- Sets depth of
vessel cylinder / equipment tank.
|
Diameter
|
Positive <numeric value>
- Sets outer
diameter of vessel.
|
Dome Height
|
Positive <numeric value>
- Sets height of
upper surface elevated above the cylinder of vessel.
|
Drain Bottom Offset
|
Positive <numeric value>
- Sets offset
between control Drain connection and bottom of equipment.
|
Drain Connection Side
|
- Puts the Drain
connection at End3 on one of the above sides of Chiller box.
|
Drain Diameter
Drain | Outer Diameter
|
Positive <numeric value>
- Sets outside
diameter of drain connection.
|
Drain Length
|
Positive <numeric value>
- Sets the length
of the pipe at drain connection.
|
Drain | Side Offset
|
Positive <numeric value>
- Sets the offset
between Drain connection and side of equipment (e.g. at End3 of Chiller unit.)
|
Drain | Top Offset
|
Positive <numeric value>
- Sets the offset
between Drain connection and top of equipment.
|
Electrical Coil Connection Diameter
|
Positive <numeric value>
- Sets outside
diameter of coil connection at End3.
|
Electrical Connection Length
|
Positive <numeric value>
- Sets length to
straight portion at electric connection at End5.
|
Electrical Connection Width
|
Positive <numeric value>
- Sets width to
portion at electric connection at End5.
|
Electric Supply Bottom Offset
|
Positive <numeric value>
- Sets the offset
between Electric Supply connection and the bottom of equipment (e.g. Chiller).
|
Electric Supply Connection Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts the Electric
Supply connection on one of the above sides of equipment.
|
Electric Supply Diameter
|
Positive <numeric value>
- Sets outside
diameter of Electric Supply connection in the equipment.
|
Electric Supply Side Offset
|
Positive <numeric value>
- Sets the offset
between Electric Supply connection and the side of equipment (e.g. Chiller).
|
Electrical Connection Side Offset
|
Positive <numeric value>
- Sets offset to
End3 connect point from left side on control box.
|
Electrical Connection Top Offset
|
Positive <numeric value>
- Sets offset
distance between End3 connect point and top of control box.
|
Fan Cylinder Height
|
Positive <numeric value>
- Sets height of
cylindrical fans placed on Chiller.
|
Fan Diameter
|
Positive <numeric value>
- Sets outside
diameter of cylindrical fans placed on Chiller.
|
Fan Direction
|
1-top
- Puts fan on top
of condenser box.
2-side
- Puts fan on side
of condenser box.
|
Fan Horizontal Offset
|
<numeric value>
- Sets offset to
fan from sides.
|
Fan Outer Diameter
|
Positive <numeric value>
- Sets outside
diameter of fans.
|
Fan Vertical Offset
|
<numeric value>
- Sets offset to
fan from top, when placed at sides.
|
Flow | Bottom Offset
|
Positive <numeric value>
- Sets vertical
offset to Flow connection from the bottom.
|
Flow | Connection Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Flow
connection at End1 on one of the sides of the equipment.
|
Flow | Diameter
|
Positive <numeric value>
- Sets outside
diameter of Flow connection at End1 in equipment.
|
Flow | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to Flow connection from the side.
|
Flue Connection Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Flue
connection on one of the above sides of boiler equipment box.
|
Flue Diameter
|
Positive <numeric value>
- Sets outside
diameter of Flue connection at End5 in Boiler equipment.
|
Flue Front Offset
|
Positive <numeric value>
- Sets horizontal
offset to Flue connection from the side of equipment.
|
Flue Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to Flue connection from the bottom of equipment.
|
Fuel Flow Rate
|
<numeric value>
- Sets a value for
the amount of fuel flow through the equipment, in GpM in Imperial and l/s in
Metric unit system. Used to calculate overall flow rate during analysis
operations.
|
Fuel Type
|
- Puts fan on top
of condenser box.
- Puts fan on side
of condenser box.
|
Gas Inlet | Bottom Offset
|
Positive <numeric value>
- Sets horizontal
offset to Gas Inlet connection from the bottom.
|
Gas Inlet | Connection Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Gas Inlet
connection on one of the above sides of boiler equipment box.
|
Gas Inlet | Diameter
|
Positive <numeric value>
- Sets outside
diameter to Gas Inlet connection.
|
Gas Inlet | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to Gas Inlet connection from the side.
|
Grille Depth
|
Positive <numeric value>
- Sets depth of
grille portion.
|
Grille Offset Horizontal
|
<numeric value>
- Sets offset to
grille portion from right side. Negative offset shifts grille to the right. 0
offset aligns grille portion in the center of panel.
|
Grille Offset Vertical
|
<numeric value>
- Sets offset to
grille portion from bottom side. Negative offset shifts grille down.
|
Grille Width
|
Positive <numeric value>
- Sets width of
grille portion.
|
Height
|
Positive <numeric value>
- Sets straight
height of vessel cylinder / equipment tank.
|
Hot Water Pipe | Length
|
Positive <numeric value>
- Sets distance
between End1 and the vessel body.
|
Hot Water Pipe | Outer Diameter
|
<numeric value>
- Sets pipe outside
diameter for End2 of water heater.
|
Inlet | Connection
Side
Outlet 1 | Connection Side
Outlet 2 | Connection Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
-
6-Bottom
- Puts the
respective inlet / outlet connection on one of the above sides of equipment
box.
|
Inlet | Length
|
Positive <numeric value>
- Sets length of
Inlet pipe at End1, in addition to Connection1 Length.
|
Inlet | Outer Diameter
|
Positive <numeric value>
- Sets outer
diameter of the inlet connection (End1) of the equipment.
|
Inlet
|
Positive <numeric value>
- Sets horizontal
offset to Inlet connection from side of equipment.
|
Inlet | Top Offset
|
Positive <numeric value>
- Sets vertical
offset to Inlet connection from top of equipment.
|
Inlet/Outlet | Top Offset
|
Positive <numeric value>
- Sets straight
height between center of End1/End2 and top of the equipment, equals default
half of total height, and can be set higher
|
Length | Straight length
|
Positive <numeric value>
- Sets straight
length of vessel cylinder / equipment tank.
|
Liquid Coil | Outer Diameter
|
Positive <numeric value>
- Sets outside
diameter D1 of coil connection at End1.
|
Liquid Coil | Side Offset
|
Positive <numeric value>
- Sets offset to
End1 connect point from right side on control box.
|
Liquid Coil | Top Offset
|
Positive <numeric value>
- Sets offset
distance between End1 connect point and top of control box.
|
Material
|
-
1-Steel
-
2-Concrete
-
3-GRP
-
4-Polyethene
-
5-Fiberglass
- Sets the storage
tank body material.
|
Mount Type
|
-
1-Vertical - mounts vessel
vertical.
-
2-Horizontal - mounts vessel
horizontal.
- Sets the mounting
orientation to the vessel.
|
No. of Compressor
|
- Sets the number
of compressor units in condenser.
Condenser Type
determines compressor count.
- Type01 /Type02: 1 Compressor.
- Type03 : 2 Compressors.
|
Number Of Air Vents
|
- Sets number of
air vents on the vent assembly on the top of Air Separator.
|
Number Of Fans
|
<integer>
- Sets number of
fan in the equipment.
|
No. Of Horizontal Bars
|
<integer>
- Sets number of
horizontal bars.
|
Number Of Strips
|
<numeric value>
- Sets number of
strips on the side of round Catch Basin.
|
No. Of Vertical Bars
|
<integer>
- Sets number of
vertical bars.
|
Offset Between Two Fans
|
<numeric value>
- Sets offset
between center of fans (for Type03).
|
Outlet 1 | Length
|
Positive <numeric value>
- Sets length of
outlet pipe at End2, in addition to Length 2.
|
Outlet 2 | Length
|
Positive <numeric value>
- Sets length of
additional outlet pipe at End3, in addition to Length 3.
|
Outlet | Diameter
|
Positive <numeric value>
- Sets outside
diameter of connection at End1.
|
Outlet | Diameter
|
Positive <numeric value>
- Sets diameter of
outlet pipe at End2.
- Sets outside
diameter of outlet connection at End1. (for Catch Basin)
|
Outlet | Length
|
Positive <numeric value>
- Sets length of
outlet pipe.
|
Pot Diameter
|
Positive <numeric value>
- Sets outside
diameter of body of Dosing Pot equipment.
|
Pot Length
|
Positive <numeric value>
- Sets body length
of Dosing Pot equipment.
|
Return | Bottom Offset
|
Positive <numeric value>
- Sets offset to
Return connection at End2 from bottom of equipment.
|
Return | Connection Side
|
-
1-Back
-
2-Front
-
3-Left
-
4-Right
-
5-Top
- Puts Return
connection at End2 on one of the sides of the equipment.
|
Return | Diameter
|
Positive <numeric value>
- Sets outside
diameter of Return connection at End2 of equipment.
|
Return | Side Offset
|
Positive <numeric value>
- Sets offset to
Return connection at End2 from side of equipment.
|
Section Height
Section Length
Section Width
|
Positive <numeric value>
- Sets dimensions
of the tank (when TankType is set Sectional).
|
Shell Inlet | Connection Side
|
-
1-Top
-
2-Bottom
-
3-Front
-
4-Back
- Puts shell inlet
connection on one of the sides of the equipment.
|
Shell Inlet | Diameter
|
Positive <numeric value>
- Sets outside
diameter of shell inlet connection of Heat Exchanger at End3.
|
Shell Inlet | Length
|
Positive <numeric value>
- Sets length of
shell inlet connection of Heat Exchanger at End3.
|
Shell Inlet | Offset
|
Positive <numeric value>
- Sets horizontal
offset distance of inlet connect point at End3 to the left of the side of heat
exchanger.
|
Shell Outlet | Connection Side
|
-
1-Top
-
2-Bottom
-
3-Front
-
4-Back
- Puts shell outlet
connection on one of the sides of the equipment.
|
Shell Outlet | Diameter
|
Positive <numeric value>
- Sets outside
diameter of shell outlet connection of Heat Exchanger at End4.
|
Shell Outlet | Length
|
Positive <numeric value>
- Sets length of
shell outlet connection of Heat Exchanger at End4.
|
Shell Outlet | Offset
|
Positive <numeric value>
- Sets horizontal
offset distance of outlet connect point at End4 to the left of the side of heat
exchanger.
|
Inlet | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to Inlet connection at End1 from the side.
|
Outlet 1 | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to Outlet1 connection at End2 from the side.
|
Outlet 2 | Side Offset
|
Positive <numeric value>
- Sets horizontal
offset to Outlet2 connection at End3 from the side.
|
Stand Height
|
Positive <numeric value>
- Sets height to
the stand attached to the vessel body of Shell and Tube heat exchanger
equipment.
|
Stand Width
|
Positive <numeric value>
- Sets width to the
stand attached to the vessel body of Shell and Tube heat exchanger equipment.
The length of stand is set internally proportionally with
the vessel diameter.
|
Strip Thickness
|
Positive <numeric value>
- Sets default
thickness to strips forming grille surface on the equipment (e.g. Catch Basin).
|
Suction Coil Side Offset
|
Positive <numeric value>
- Sets offset to
End2 connect point from right side on control box.
|
Suction Coil Top Offset
|
Positive <numeric value>
- Sets offset
distance between End2 connect point and top of control box.
|
Suction Coil Outer Diameter
|
Positive <numeric value>
- Sets outside
diameter D2 of coil connection at End3.
|
Tag
|
<alpha-numeric characters>
- Sets tag value
visible in output of drawing composition in dynamic view.
Separate tag strings with a semi colon.
Default tag is OutDoor Condenser.
|
Tank Height
Tank Length
Tank Width
|
Positive <numeric value>
- Sets dimensions
of sides of tank. Modified using the Section dimensions.
|
Tank Type
|
|
Inlet | Top Offset
|
Positive <numeric value>
- Sets offset
distance between End2 connect point and top of equipment.
|
Inlet | Top Offset
|
Positive <numeric value>
- Sets vertical
offset to Inlet connection at End1 from the side.
|
Total Length
|
Positive <numeric value>
- Sets distance
between End1 and End2 of equipment.
|
Total Height
|
<Positive numeric value>
- Sets the height
from the base to the discharge port/manifold end 2 surface.
- Sets straight
height from End3 connection at bottom to the vent at top, equals default twice
the Height1.
|
Tube Connection Side
|
- Sets tube inlet
and outlet connections to either Left or Right side of unit.
|
Tube Inlet | Diameter
|
Positive <numeric value>
- Sets outside
diameter of tube inlet connection of Heat Exchanger at End1.
|
Tube Inlet | Length
|
Positive <numeric value>
- Sets length of
shell inlet connection of Heat Exchanger at End1.
|
Tube Inlet | Offset
|
Positive <numeric value>
- Sets horizontal
offset distance of inlet connect point at End1 to the center of the side of
heat exchanger the inlet is connected.
|
Tube Outlet | Diameter
|
Positive <numeric value>
- Sets outside
diameter of tube outlet connection of Heat Exchanger at End2.
|
Tube Outlet | Length
|
Positive <numeric value>
- Sets length of
shell outlet connection of Heat Exchanger at End2.
|
Tube Outlet | Offset
|
Positive <numeric value>
- Sets horizontal
offset distance of outlet connect point at End2 to the center of the side of
heat exchanger the outlet is connected.
|
Tundish Diameter
|
Positive <numeric value>
- Sets outside
diameter of body of Tundish equipment.
|
Tundish Length
|
Positive <numeric value>
- Sets body length
of Tundish equipment.
|
Vent Assembly Diameter
|
Positive <numeric value>
- Sets outside
diameter of vent assembly housing the air vents on the top of equipment.
|
Wall Thickness
|
Positive <numeric value>
- Sets thickness of
walls of tank unit.
|
Width
|
Positive <numeric value>
- Sets width of
equipment tank /vessel cylinder.
|