Air Flow Rate |
Positive <numeric value>
This property is used by the Analysis tool for calculating upstream air flow rates for connected elements. |
Angle |
<angle value> between 90° and 180°
- Sets the angle the spout curvature covers.
|
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Connection 3 | Length (L3) |
Positive <numeric value>
- Sets the length at gooseneck base that adds an offset to mount it on a roof curb.
Enabled when Cowl Setting property is set to 1-No Cowl. |
Cowl Depth Cowl Length
Cowl Width |
Positive <numeric value>
- Sets the Depth, length and Width of the cowl, respectively.
Enabled when Cowl Setting property is set to 2-With Cowl. |
Cowl Setting |
- 1-No Cowl - without cowl assembly at base.
- 2-With Cowl - cowl attached at the base end to prevent back flow.
- Sets or no Cowl to the Gooseneck.
Gooseneck without cowl enables L3 property. |
Radius |
Positive <numeric value>
- Sets the radius of the curvature formed by the gooseneck.
|
Transition1 Length, Transition2 Length
|
Sets the transition length. Transitions coupled at base end and along the upstream at tip respectively. |