Air Outlet Position
|
|
Box | Height
Box | Length
Box | Width
|
Positive <numeric value>
- Sets dimensions
of sides of radiator box.
|
Connection | Side
|
- Sets inlet and
outlet connections to either Left or Right side of unit.
|
Convector | Type
|
-
1-Twins
-
2-TwinTube
-
3-Stacked
- Sets one of the
types of convector to Sill Twin and Trench Twin convectors.
Single
- By
default, sets type of convector Single to Sill Single and Trench Single
convectors.
|
Depth
|
Positive <numeric value>
- Sets depth
dimension of convector body.
|
Connection 1 | Length (L1)
Connection 2 | Length (L2)
Connection 3 | Length (L3)
Connection 4 | Length (L4)
|
Positive <numeric value>
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
- Sets and sizes
end with a male connection.
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2;fe-.13 creates a flange at End1
with size 2, and a female connection at End2 with an overall reduction of
component's dimensions of .13
|
Flow | Connection Side
|
- Sets either or
both of sides on radiator box for flow connection.
|
Flow | Length
|
Positive <numeric value>
- Sets the straight
length of Flow connection.
|
Flow Location
|
-
1-Panel 1
-
2-Panel 2
-
3-Panel 3
|
Flow | Outer Diameter
|
Positive <numeric value>
- Sets outer
diameter of flow connection. Keeps Return diameter same.
|
Flow Top Offset
|
Positive <numeric value>
- Sets the offset
distance between the flow connection and the top of the unit.
|
Flow Valve Type
|
-
1-Thermostatic
-
2-Non Thermostatic
- Sets type of flow
valve to either one.
|
Inlet | Length
|
Positive <numeric value>
- Sets the straight
length of Inlet at End1.
|
Length
|
Positive <numeric value>
- Sets length
dimension of convector body.
|
Mounting Height
Mounting Length
Mounting Width
|
Positive <numeric value>
- Sets dimensions
of sides of mounting unit on radiator panel.
|
Convector | No. of Bars
|
<integer>
- Sets number of
bars to outlet panel of equipment.
|
No. of Grille Bars
|
<integer>
- Sets number of
grille bars on grille surface on the device.
|
Number Of Sections
|
<integer>
- Sets number of
sections in radiator column.
|
Outlet | Length
|
Positive <numeric value>
- Sets the straight
length of Outlet at End2.
|
Panel Type
|
-
1-Single
-
2-Double
-
3-Tripple
|
Radiator Type
|
- Sets type of
radiator to either one.
|
Return | Connection Side
|
- Sets either or
both of sides on radiator box for return connection.
|
Return | Length
|
Positive <numeric value>
- Sets the straight
length of Return connection.
|
Return Location
|
-
1-Panel 1
-
2-Panel 2
-
3-Panel 3
|
Return | Outer Diameter
|
Positive <numeric value>
- Sets outer
diameter of return connection. Follows Flow diameter.
|
Return Top Offset
|
Positive <numeric value>
- Sets the offset
distance between the return connection and the top of the unit.
|
Return Valve Type
|
-
1-Thermostatic
-
2-Non Thermostatic
- Sets type of
return valve to either one.
|
Width
|
Positive <numeric value>
- Sets width
dimension of convector body.
|