AHU Height AHU Width
|
Positive <numeric values>
- Display height and width dimensions set of the AHUs.
|
Cell Symbol Name |
<cell name>;<cell name>;<cell name>;<cell name>;scale=<numeric value>
- Sets cell displayed on the device surfaces.
- Scale entry fits cell proportionally to extents of device.
|
Configuration |
Defines chambers, sizes and locates HVAC and plumbing ports on the AHU. |
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Connection | Length |
Positive <numeric value>
- Sets length of straight portion at all connection of AHUs.
|
No. Plumbing Connections |
<Integer>
- Sets number of plumbing connections.
|
Plumbing Connection | Outer Diameter |
Positive <numeric value>; <numeric value>; <numeric value> ... times the number of plumbing connections.
- Sets the outer diameter of the plumbing connections.
|
Total Length (L) |
Positive <numeric value>
|