Air Handling Unit types
The AHU group comprises in-build inline, and stacked AHUs supplied in Mechanical discipline. The default AHUs available in the applications are loaded via the AHU Library in AHU List and be placed as an individual AHU.
Key In Syntax
Follows the
Placement Key In
syntax.
BMECH PLACE COMPONENTBYNAME <schema name> <item name> dsc=HVAC
Types of AHUs
The below list of fittings illustrates the possible <schema name> <item name> used in above key in syntax, for each AHU and the description of the component.
RectangularAHUs1 AHU1 | Rectangular AHU1 — A standard rectangular Air Handling Unit with a Fluid IN and Fluid OUT connections. The purpose of this equipment is to collect and mix outdoor air with that returning from the building space. |
RectangularAHUs2 AHU2 | Rectangular AHU2 — A multi chamber rectangular Air Handling units in a row with a Fluid IN and Fluid OUT connections at opposite ends. |
RectangularAHUs3 AHU3 | Rectangular AHU with 3 Ends — Rectangular Air Handling terminal units with 3 ends to connect to additional branch or unit. |
RectangularAHUs4 AHU4 | Rectangular AHU with 4 Ends — Rectangular Air Handling terminal units with 4 ends. Provides additional supply and return to connect to branch or unit. |
RectangularAHUs5 AHU5 | Rectangular AHU with 5 Ends — Rectangular Air Handling terminal units with 5 ends. Provides additional supply and return to connect to branch or unit. |
rectangularInlineAHUs1 "InlineAHU" | Inline AHU - (Blower) — Configuration: Blower |
RectangularInlineAHUs2 "InlineAHU" | Inline AHU - (Blower, PreFilter) — Configuration: Blower, Pre Filter |
RectangularInlineAHUs3 "InlineAHU" | Inline AHU - (Blower, Cooling Coil, PreFilter) — Configuration: Blower, Pre Filter, Cooling Coil |
RectangularInlineAHUs4 "InlineAHU" | Place Inline AHU - (S.A. Plenum, Fine Filter, Blower, PreFilter) — Configuration: Blower, Pre Filter, S.A. Plenum, Fine Filter |
RectangularInlineAHUs5 "InlineAHU" | Inline AHU - (S.A. Plenum, Fine Filter, Blower, PreFilter, Mixing Chamber) — Configuration: Blower, Pre Filter, S.A. Plenum, Fine Filter, Mixing Chamber |
RectangularInlineAHUs6 "InlineAHU" | Inline AHU - (S.A. Plenum, Fine Filter, Blower, Cooling Coil, PreFilter, Mixing Chamber) — Configuration: Blower, Pre Filter, S.A. Plenum, Fine Filter, Mixing Chamber, Cooling Coil |
RectangularInlineAHUs7 "InlineAHU" | Inline AHU - (S.A. Fan, Cooling Coil, PreFilter, Mixing Chamber, Exhaust Chamber, R.A. Fan) — Configuration: Pre Filter, S.A. Fan, Mixing Chamber, Cooling Coil, Exhaust Chamber, R.A. Fan |
RectangularInlineAHUs8 "InlineAHU" | Inline AHU - (S.A. Plenum, HEPA Filter, Fine Filter, Blower, Heating Coil, Cooling Coil, PreFilter, Mixing Chamber) — Configuration: Blower, Pre Filter, S.A. Plenum, Mixing Chamber, Cooling Coil, Heating Coil, Fine Filter, HEPA Filter |
RectangularInlineStackedAHUs1 "InlineAHU" | Stack Inline AHU1 — Level 1 - Configuration: Blower, Pre Filter, Mixing Chamber, Cooling Coil Level 2 - Configuration: Fine Filter, HEPA Filter, S.A. Plenum |
RectangularInlineStackedAHUs2 "InlineAHU" | Stack Inline AHU2 — el 1 - Configuration: Blower, Pre Filter, S.A. Plenum, Mixing Chamber, Cooling Coil, Heating Coil, Fine Filter, HEPA Filter Level 2 - Configuration: Blower, Pre Filter, E.A. Plenum |
RectangularInlineStackedAHUs3 "InlineAHU" | Stack Inline AHU3 — Level 1 - Configuration: Blower, Pre Filter, Mixing Chamber, Cooling Coil, Heating Coil, Humidifying Section Level 2 - Configuration: Fine Filter, S.A. Plenum |
RectangularInlineHRUAHUs "InlineAHU" | Rectangular Inline HRU AHU — Level 1 - Configuration: Blower, Pre Filter, S.A. Plenum, Cooling Coil, Heat Recovery Unit Level 2 - Configuration: Blower, Pre Filter, S.A. Plenum, Heat Recovery Unit |
RectangularInlineVerticalAHUs1 "InlineAHU" | Rectangular Inline Vertical AHU1 — Level 1 - Configuration: Filter, Cooling Coil Level 2 Configuration: Blower |
RectangularInlineAIRWASHERAHUs "InlineAHU" | Rectangular Inline AIRWASHER AHUs — Configuration: Blower, Washer System, Filter |