PartL NI: Results Tab

Contains the resulted reports derived from PartL NI calculations. The program checks criteria for PartL2A compliance. All checks need to be satisfied before overall compliance is achieved. Actual compliance with PartL2A involves further criteria such as ensuring the building is constructed consistent with BER and operated in an energy efficient manner. These additional criteria are outside the scope of this calculation program.

SettingDescription
Northern Ireland Building Regulations Part F 2012 A Building rating document is automatically produced and this document is displayed. The document provides access to various key calculation results including the following.
  • The energy used per square meter (kWh/m2) by the actual and notional buildings for heating, cooling, auxiliary energy uses (pumps and fans), lighting and domestic hot water.
  • The resulting CO2 emissions (kgCO2/m2) from the actual and notional buildings.
CO2 emissions mandatory requirement Carbon dioxide emissions for the actual building (BER) is computed by SBEM. A notional building is automatically constructed using the actual building data and limiting U values and glazed areas, as defined in PartL. The carbon dioxide emission for the notional building is computed by SBEM.