Air Intake Diameter |
Positive <numeric value>
- Sets outside diameter (D1) of Air Intake connection at End1.
|
Air Intake Length |
Positive <numeric value>
- Sets the straight connection length (L1) at End1.
|
Air Intake Side Offset |
Positive <numeric value>
- Sets offset distance between End1 connect point and side of box. Minimum offset equals radius of Air Intake.
|
Air Intake Top Offset |
Positive <numeric value>
- Sets offset distance between End1 connect point and top of box. Default offset equals radius of Air Intake.
|
Base Body | Width |
Positive <numeric value>
- Sets width of base of unit.
|
Body | Height |
Positive <numeric value>
- Sets height of the body, including control box.
|
Body | Length |
Positive <numeric value>
- Sets height of the condenser body.
|
Box | Depth Box | Height
Box Length Box | Width
|
Positive <numeric value>
- Sets dimensions of sides of unit.
|
Box | Separation Space |
Positive <numeric value>
- Sets the gap between adjacent Box.
|
Center Body | Width |
Positive <numeric value>
- Sets width of the center body of unit.
|
Coil Connection Length |
Positive <numeric value>
- Sets the straight length of inlet/outlet coils.
|
Coil Inlet Side Offset |
Positive <numeric value>
- Sets horizontal offset to coil inlet from the side.
|
Coil Inlet Top Offset |
Positive <numeric value>
- Sets vertical offset to coil inlet from the top.
|
Coil Location |
-
1-back
-
2-bottom
-
3-left
-
4-right
- Puts heating/cooling coil and drain connections on one of the above sides of unit.
|
Coil Inlet | Connection Side |
- Sets one of the above sides of the control box to place inlet of coil.
|
Coil Outlet | Connection Side |
- Sets one of the above sides of the control box to place outlet of coil.
|
Cooling Coil | Outer Diameter |
Positive <numeric value>
- Sets outside diameter of inlet/outlet coil connections.
|
Coil Outlet Side Offset |
Positive <numeric value>
- Sets horizontal offset to coil outlet from the side.
|
Coil Outlet Top Offset |
Positive <numeric value>
- Sets vertical offset to coil outlet from the top.
|
Coil | Placement View |
- Sets one of the above sides of the unit to place coils.
|
Connection1 | Length (L1) |
Positive <numeric value>
- Sets the straight length at End1.
|
Connection2 | Length (L2) |
Positive <numeric value>
- Sets the straight length at End2.
|
Connection1 | Side |
-
1-back
-
2-front
-
3-bottom
-
4-top
- Puts End1 connection on one of the above sides of unit.
|
Connection1 | Type |
- Sets connection 1 of control unit ducted or grilled type.
Type01unit always has connection1 and connection2 predefined to Duct–Grille. Type02 to Grille–Grille and Type03 to Duct–Duct. |
Connection2 | Side |
- Puts End2 connection on one of the above sides of unit.
Not both Connection1 and Connection2 sides be assigned bottom, Connection1 sets to top. |
Connection2 | Type |
- Sets connection 2 of control unit ducted or grilled type.
|
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Cooling Coil Inlet | Side Offset |
Positive <numeric value>
- Sets horizontal offset to cooling coil inlet from the side.
|
Cooling Coil Inlet | Top Offset |
Positive <numeric value>
- Sets vertical offset to cooling coil inlet from the top.
|
Cooling Outlet Coil | Side Offset |
Positive <numeric value>
- Sets horizontal offset to cooling coil outlet from the side.
|
Cooling Outlet Coil | Top Offset |
Positive <numeric value>
- Sets vertical offset to cooling coil outlet from the top.
|
Cooling Coil | Type |
-
0-none
-
1-plumbing
-
2-electrical
- Sets the type of cooling coil.
Type plumbing adds provision for inlet/outlet of pipes. The Heating Coil Type is always set opposite to that of Cooling Coil Type. Both should not be none type, at least one type is set plumbing
|
Drain | Bottom Offset |
Positive <numeric value>
- Sets vertical offset to drain outlet from the bottom.
|
Drain Length |
Positive <numeric value>
- Sets length of drain outlet.
|
Drain | Outer Diameter |
Positive <numeric value>
- Sets outside diameter of drain connection.
|
Drain | Side Offset |
Positive <numeric value>
- Sets horizontal offset to drain outlet from the side.
|
Duct Connection Length |
Positive <numeric value>
- Sets length for the grille connection at end 1.
|
Front Body Height |
Positive <numeric value>
- Sets height of the front body of the fitting, less than Body Height.
|
Gas Inlet | Diameter |
Positive <numeric value>
- Sets outside diameter of Gas Inlet.
|
Gas Inlet | Length |
Positive <numeric value>
- Sets the straight length of Gas Inlet.
|
Gas Inlet | Side Offset |
Positive <numeric value>
- Sets offset distance between Gas Inlet connect point and side of box.
|
Gas Inlet | Top Offset |
Positive <numeric value>
- Sets offset distance between Gas Inlet connect point and top of box.
|
Grille Connection Length |
Positive <numeric value>
- Sets length for the grille connection at end 2.
|
Heating Coil Inlet | Side Offset |
Positive <numeric value>
- Sets horizontal offset to heating coil inlet from the side.
|
Heating Coil Inlet | Top Offset |
Positive <numeric value>
- Sets vertical offset to heating coil inlet from the top.
|
Heating Coil Outlet | Side Offset |
Positive <numeric value>
- Sets horizontal offset to heating coil outlet from the side.
|
Heating Coil Outlet | Top Offset |
Positive <numeric value>
|
Heating Coil | Type |
-
0-none
-
1-plumbing
-
2-electrical
- Sets the type of heating coil.
Type plumbing adds provision for inlet/outlet of pipes. The Cooling Coil Type is always set opposite to that of Heating Coil Type. Both should not be none type, at least one type is set plumbing.
|
Modular Type |
-
1- Condensing
-
2- Atmospheric
- Sets modular type. Drain properties effect when type is set to Condensing.
|
No. of Column |
<integer>
- Sets number of columns of radiator boxes in modular.
|
No. of Rows |
<integer>
- Sets number of rows of radiator boxes in modular.
|
|
|
Return | Diameter |
Positive <numeric value>
- Sets outside diameter of Return Outlet.
|
Return | Length |
Positive <numeric value>
- Sets the straight length of Return Outlet.
|
Return | Side Offset |
Positive <numeric value>
- Sets offset distance between Return connect point and side of box.
|
Return | Top Offset |
Positive <numeric value>
- Sets offset distance between Return connect point and top of box.
|
Service Area Side |
-
1-Back
-
2-Left
-
3-Right
-
4-All
|
Service Thickness |
Positive <numeric value>
- Sets distance between modular boxes and service panel, allowing sufficient gap.
|
Supply Diameter |
Positive <numeric value>
- Sets outside diameter of Supply Inlet.
|
Supply Length |
Positive <numeric value>
- Sets the straight length of Supply Inlet.
|
Supply Side Offset |
Positive <numeric value>
- Sets offset distance between Supply connect point and side of box.
|
Supply Top Offset |
Positive <numeric value>
- Sets offset distance between Supply connect point and top of box.
|
Tag |
<alpha-numeric characters>
- Sets tag value visible in output of drawing composition in dynamic view. Separate tag strings with a semi colon.
|