Bar Thickness
|
Positive <numeric value>
- Sets the
thickness of the bars forming grille. Disabled for Channel Grate / Parking
Drain.
|
Body | Cone Diameter
|
Positive <numeric value>
- Sets the diameter
of the cone nearest the grille.
|
Body | Cone Height
|
Positive <numeric value>
- Sets the height
of the tapered portion of the floor drain.
|
Body | Cone Top Diameter
|
Positive <numeric value>
- Sets the diameter
of the cone nearest the connection point.
|
Connection 1 | Length (L1)
Connection 2 | Length (L2)
Connection 3 | Length (L3)
Connection 4 | Length (L4)
Connection 5 | Length (L5)
Connection 6 | Length (L6)
|
Positive <numeric value>
- Sets the straight
length at respective End#.
- Connection 1 | Length (L1) - Port 1
length.
In case of Floor Drain 4/5/6Way;
- Connection 2 | Length (L2) - Port 2
length,
- Connection 3 | Length (L3) - Port 3
length,
- Connection 4 | Length (L4) - Port 34
length,
- Connection 5 | Length (L5) - Port 5
length,
- Connection 6 | Length (L6) - Port 6
length.
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
- Sets and sizes
end with a male connection.
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2; creates a flange at End1 with size
2, and fe-.13; creates a female connection at End1 with an overall reduction of
component's dimensions of .13
|
Connection | Length
|
Positive <numeric value>
- Sets length of
straight portion at connection at END1.
|
Connection | Offset
|
Positive <numeric value>
- Sets distance of
connection End1 from the left of channel grate.
|
Connection | Side
|
- 1-Bottom– across
width.
- 2-Side– across
height.
- Sets outlet
connection End1 on either sides.
|
Depth
|
Positive <numeric value>
- Sets depth of the
drain, that determines the distance the grille is away from the End connection.
|
Diameter
|
Positive <numeric value>
- Sets the diameter
of the main pipe of floor drain, usually follows End1 diameter (D1).
Note: For
Floor Drains -4/5/6Way, the port diameters D3, D4, D5, and D6 should always be
set positive and less than the body diameter D1Ø (Maximum).
|
Flange Offset
|
Positive <numeric value>
- Sets the flange
offset appropriate with the height of floor trough.
|
Flange | Size
|
Positive <numeric value>
- Sets the flange
dimension, exterior to the floor trough dimension.
|
Frame | Width
|
Positive <numeric value>
- Sets the width of
the frame to control the area of grills forming with bars.
|
Grille | Diameter
|
Positive <numeric value>
- Sets the outside
diameter of the grille.
|
Grille | Thickness
|
Positive <numeric value>
- Sets the
thickness of the grille portion.
|
Height
|
Positive <numeric value>
- Sets the height
of the floor trough assembly.
|
Length
|
Positive <numeric value>
- Sets the length
of the floor drain assembly.
|
Mount Height
|
Positive <numeric value>
- Sets the length
of the oblique grate above body cone.
|
No. Of Bars
|
<integer>
- Sets number of L
shape bars.
|
No. Of Horizontal Bars
|
<integer>
- Sets number of
vertical bars.
|
No. Of Vertical Bars
|
<integer>
- Sets number of
horizontal bars.
|
Port 3 | Length
Port 4 | Length
Port 5 | Length
Port 6 | Length
|
Positive <numeric value>
- Sets length of
pipe of respective port branches on main pipe.
|
Port4 Connection Side
|
- 1-Opposite –
opposite of Port3.
- 2-Side –
perpendicular to Port3.
- Sets the location
of Port4 on the main pipe either opposite to Port3 or on side at 90°.
|
Stub Length
|
Positive <numeric value>
- Sets the length
of the stub outlet.
|
Width
|
Positive <numeric value>
- Sets the width of
the floor trough.
|