Orientation
|
The orientation region of the dialog controls the operator
orientation or angle relative to the valve. Orientation is relative to fitting
axis; angle (degree).
- X: Primary — Sets
front and back rotation of operator along the valve axis in degrees.
- Y: Tertiary — Sets
rotation of operator perpendicular to the valve axis in degrees. Positive
values rotate the operator towards End2 and negative values rotate the operator
towards End1.
- Z: Secondary — Sets
the orientation of the operator relative to operator's shaft axis.
|
Parameters
|
The parameters region of the dialog controls the type of
operator and its dimensions.
- Operator Type — Used
to select sets the operator type.
The available types are a handwheel, a wrench, an electrical
box, a gear box, a calibrated, a pneumatic or a thermostatic.
Note: The
appearance of the dialog options changes depending upon which operator is
selected.
|
for Gear
|
- A — Sets the
vertical offset distance between the valve axis the gear box's centerline.
- B — Sets the
distance between the gear box's centerline to the end of the gear actuation
shaft.
- C — Sets the
gear operator hand control diameter.
- D — Sets the
horizontal offset distance between the valve axis and the hand control.
- E —Sets the
horizontal offset distance between the gear actuator shaft and the hand control
axis.
|
for Electric
|
-
A — Sets the electrical box's larger
size dimension, i.e. actuator width.
- B — Sets the
offset distance between the valve and the outermost surface of the electrical
box.
- C — Sets the
electrical actuator shaft diameter.
- D — Sets the
length of the actuator.
|
for Handwheel (and Calibrated, Pneumatic or Thermostatic)
|
-
A — Sets the handwheel's diameter.
- B — Sets the
offset distance between the valve and the handwheel.
- C — Sets the
handwheel shaft diameter.
|
for Wrench
|
- A — Sets the
vertical offset distance between the valve axis and the wrench.
- B — Sets the
lever length, the horizontal offset distance between the valve axis and the end
of wrench.
|
OK
|
Applies dialog settings to the active component.
|
Cancel
|
Dismisses and closes the dialog.
|