Base Offset
|
<numeric value>
- Displays the Base
Offset set in the
Place dialog while placing a pipe.
The value reflects when a pipe is being modified.
|
Body | Diameter
|
Positive <numeric value>
- Sets cylinder
diameter for main body of coupling, higher than End diameters.
|
Cap | Length
|
Positive <numeric value>
- Sets the distance
between the connect point (End1) and the start of the dome.
|
Connection 1 | Length (L1)
|
Positive <numeric value>
- Sets length of
male or female connection for End1.
Set End Type to male or female to see change in geometry. If
End Type is flange, the connection point moves.
|
Connection 2 | Length (L2)
|
Positive <numeric value>
- Sets length of
male or female connection for End2.
|
Convolutions
|
Positive <numeric value>
- Preset number of
convolutions based on movement capability and/or spring rate, making bellows
flexibility possible.
The number of convolutions depends upon the amount of
movement the bellows must accommodate or the force that must be used to
accomplish this deflection.
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
- Sets and sizes
end with a male connection.
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2;fe-.13 creates a flange at End1
with size 2, and a female connection at End2 with an overall reduction of
component's dimensions of .13
For
Flex Bellows, The
End Type is selectable, either:
- 1-Flange – Adds
flanges to both ends.
- 2-Plain – Sets no
flanges to the ends.
|
Dome Height
|
Positive <numeric value>
- Sets the height
of the dome bulge.
|
Flange1 Diameter,
Flange2 Diameter
|
Positive <numeric value>
- Sets the outer
diameters of flanges for Flange End Type flex bellows.
|
Female Connection Diameter
|
Positive <numeric value>
- Reduced branch
outside diameter at End2.
|
Hub Length
|
Positive <numeric value>
- Sets the length
of the hub body.
|
Inlet | Outer Diameter
|
Positive <numeric value>
- Outside inlet
diameter of socket.
|
Male Connection Diameter
|
Positive <numeric value>
- Main branch
outside diameter at End1 of union fitting.
|
Minimum Length
|
Positive <numeric value>
- Sets minimum
length. Duct cannot be manipulated to segments smaller than Minimum Length
property.
|
Outlet | Outer Diameter
|
Positive <numeric value>
- Outside outlet
diameter of socket.
|
Pipe Length /
Total Length (L)
|
Positive <numeric value>
- Sets duct length
with a positive value greater than or equal to value of Minimum Length
property.
- Displays flex
linear length. Set by default.
|
Pipe Outer Diameter
|
Positive <numeric value>
Note: The
value includes also the 2xWall Thickness.
|
Ridge Distance
|
Positive <numeric value>
- Sets the spacing
of ridges.
|
Ridge Numbers
|
Positive <integer>
- Sets the number
of ridges.
|
Slope Method
|
-
Rise/Run
-
Degree
-
% Precent
<active method set in Apply Slope>
- Displays slope
method currently set in the Apply Slope setting.
|
Slope Value
|
<numeric value>
- Displays slope
value appropriate with the active Slope Method.
|
Tab | Height
Tab | Length
Tab | Width
|
Positive <numeric value>
- Sets the cubical