To Create Cross Bolting connection
All straight standard shapes and polyplates are supported, except for arced shapes and arced polyplates. When using shapes other than standard shapes, the obtained result may not be as expected. Only existing bolt styles are available, there is no link to the bolt style generator from within the Cross Bolting dialog. Only normal/through holes are supported.
How drilling direction is defined?
The below table illustrates how the drilling direction is
calculated:
| First Valid Connecting Member | |||
| Shape | Polyplate | ||
| Support | Shape | The drilling direction is the cross product between both shapes Z orientation. If the shapes have the same Z orientation and aligned centerlines, the drilling direction is either the X or Y orientation of one of the shapes. | The drilling direction is the Z orientation of the connecting polyplate. |
| Polyplate | The drilling direction is the Z orientation of the supporting polyplate. | The drilling direction is the Z orientation of the supporting polyplate. | |
(
.