AutoConnect Data Manager - Connection Data tab
Provides all the information on the connection types. This information is taken from the record that was highlighted on the Record Tab and displayed here.
.
There are four connection types for each project. The
connection database ?AutoConnectData.mdb? located in the
project folder include ClipAngle, ShearPlate, EndPlate and BasePlate table.
These four connection databases are not unique to each record made on the other
tab. If you change the connections here for
Baseplate for example, it will change the connections
for all your records in this project where connection type is set to Base
Plate, irrespective of sizes.
| Setting | Description |
|---|---|
| Connection Name / Connection Definition | Displays the name of the connection and the connection definition, respectively, set in the Record Setup tab. |
| (Connection Type) tab | Displays the connection type (out of four) of currently selected record in the connection record list in the Record Setup tab. |
| (Connection Data) list | Displays the connection data of current connection in
a tabulated form. The data columns in terms of connection attributes are
populated from the database. The
Depth and
PS_Con_Tmp, are the mandatory in order for
AutoConnect to function properly.
|
Working with connection database
In order to edit this database a right-click anywhere in the database area and selecting the ?global edit? option opens the Autoconnect Web Angle Connection dialog.
The predefined
templates appear here to select/change and apply. The
actual connection to be used can be selected here from the Template list. The
depth field is related to the size of the member being
connected. The depth field in global edit appears grey. it is locked as it is
unique and is set once, and cannot be repeated. Adding new record of existing
depth prompts warning message. Global edit therefore will not let change all
depths to the same value. During global editing, any field left blank will not
be changed but any field with a value in it will have that value placed in all
of the records.