Used to define
gusset dimensions and sets the bolting and group options.
Setting
Description
Gusset Settings
Length ? Sets
the gusset plate dimension in a direction parallel to the cross-sectional X
axis of the shape selected. Enter a positive value to determine the length. A
negative value or value of 0 is not permitted. The default is 75 or 3 depending
on the units setting.
Width ? Sets
the gusset plate dimension in a direction parallel to the cross-sectional Y
axis of the shape selected. Enter a positive value to determine the length. A
negative value or value of 0 is not permitted. The default is 75 or 3 depending
on the units setting.
Thikness ? Sets
the gusset plate thickness. Enter a positive value to determine the thickness.
A negative value of value of 0 is not permitted. The default is 10 or 0.5
depending on the units setting.
Chamfer ? Sets
the gusset plate horizontal and vertical chamfer distances. The first field
sets plate chamfer in X-direction and the second set it in the Y-Direction.
Enter a positive or negative value to determine the horizontal and vertical
clearance for the shape's internal fillet. A value of 0 indicates no chamfer.
The default is 0.
Options
Group ? When checked, the selected shape, gusset plates, brace
shapes and bolts are arranged to form a group. If the selected shape is already
part of an existing group then the created objects are added to that group.
With
Bolts - When checked, the bolts are also added to that group.
Check
Flat File ? When checked, the option checks the flat file shape
table for a shape which matches the specified gusset plate width and thickness
and uses a shape in preference to a plate. The shape database checked is
controlled by the setting of
DEFAULTWIDEFLATFILE in the
ProSteel 3D configuration file. Otherwise,
a plate is created.
Tolerance ?
Enabled when
Check Flat File is set. Sets the
tolerance for creation of flat.
Continuous Purlin
Longer
Side: It creates a connection on the longer side of a purlin.
Shorter
Side: It creates a connection on the shorter side of a purlin.
Both
Sides: It creates connection on both side of a continuous purlin.
Note:"Continuous Purlin" group-box is enabled
when bracing is placed on 1 purlin and disabled when bracing is placed on 2
purlins.