Purlin - Connections tab
Notice: If
you have selected alternative insertion on the base of two main girders, the
Connections tab will be displayed in addition.
| Setting | Description |
|---|---|
| Which page | Sets which side the settings have to be valid. You can define both sides simultaneously or each single side individually. |
| No connection | When checked, parts are only inserted; no connection is created at selected end. |
| Cope | When checked, the girders are coped. The cope
dimensions and template selection is enabled. You either select a previously
defined template or the simplified specifications are valid.
|
| Web angles | If you want one of the following connections, select the previously defined template. Adds web angle connection by template by selected end. |
| Shear plates | Adds shear plate connection by template by selected end. |
| End plates | Adds endplate connection by template by selected end. |