Cope

Used to cope steel elements.

Accessed from:

Dialog Controls

Setting Description
OK Closes the dialog and save your changes.
Cancel Closes the dialog without saving changes.
Help Opens online help.
Template Saves and retrieve settings to be used on other projects.
Clone Transfers the data of the current cope directly to several copes (must be created as new copes).
Favorites
  • Current Settings - Select when you haven't created any template and you want to use the current settings of the dialog instead.
  • Bentley/Default - Select when you want to use the application default settings template and you don't want to use the current settings of the dialog instead.
Allows an unknown shape to be clicked. The flange thickness is then entered in the input fields for 1. Top Flange Inside and 5. Bottom Flange. If you have entered a value in the +Distance field, this value is added.
Show /Hide Preview Opens or closes, respectively, a flyout panel to display an illustration based on the tool.

Dimensions tab

Setting Description
Layout Selects the shape of the cope. The different variants are shown in the picture below:
Figure 1. Before coping is shown (upper left, shapes overlap), contour (upper right). Bottom from left to right: Fit Shape Start (the normal cope), Fit Shape Middle and Fit Shape End.
Corner Layout
  • Edge ? The copes at the shape radii are carried out with a chamfer.
  • Radial ? The copes at the shape radii are carried out with adapted radii. In the Radius input field, the determined radius can be modified later.
  • Access Holes ? The holes are drilled in the inner corners of the cope. In the Radius input field, the radius of the drill holes can be preset.
From Inner Flange/Center When From Inner Flange is on, the Distances are measured from the inner flange edges. When off, the Distances are measured from the outer flange edges.

When From Center is on, the Distances are measured from the flange center lines. When off, the Distances are measured from the inner or outer flange edges depending upon the From Inner Flange setting.

Figure 2. 1) Outer edges, 2) Center lines
Distances
  1. Top Flange Inside
  2. Top Flange Edge
  3. Top Flange Outside
  4. Web Distance
  5. Bottom Flange
  6. Bottom Flange Edge
  7. Bottom Flange
  8. Radius
+ Distance: This value is added to the result of the function GET FLANGE THICKNESS.
Both Sides Equal The bottom of the notch is carried out with the data of the top and the data are transferred into the fields.
Exchange Sides The values of top and bottom are exchanged with each other so that you can turn the connection.

Data tab

Setting Description
List Lists previously defined notches from a database. You can create these database files using any dBASE-editor. You can also predefine a certain number of the most frequent notches.

The different List fields display the cope data, which are the base of the connection. Apart from this you can select the desired notch by selecting an entry.

Key-in: prosteel cope