# | Item | Description |
1415987 | 2D deck decoration issue | In some files, 2d deck outlines are drawn incorrectly going straight from end to end instead of following the deck curvature. Does not affect beam layout. |
1413706 | Descartes License: Access Denied message | 'Bentley Descartes License - Access Denied' message pops up when opening files. This happens after installing newer versions of Bentley software with latest Connection clients (23.00.01.25). |
1416074 | "Import GCP file" when connected to PW, will allow user to pick from PW folder | "Import GCP file" when connected to PW, will now allow user to pick from PW folder |
1416074 | "Import GCP file" can now point to specific folder to open by default | Default new folders added with example gcp files When not connected to ProjectWise, and the user clicks the "Import GCP File" button, the directory the user specifies should come from a configuration variable in _Bridge Default Standards - Imperial.cfg or - Metric.cfg OBM_GCP_DIR = $(BRIDGE_ORGANIZATION_STANDARDS)OpenBridge Modeler/GC |
1416078 | Editing Rebar requires ProConcrete license | Editing existing reinforcement incorrectly requires ProStructures License activation. |
1416089 | Schedule Generator does not launch despite activating ProStructures License | Even after activating ProStructures License, unable to use Schedule Generator in the Structures Detailing Tab. |
1422174 | Synch to iTwins: Missing Item Type values when using lookup tables | On Collaborate Tab, and explicit Item Types Save Button has been added. This must be used after any change and prior to Synch to iTwin step. |
1419555 | Synch to iTwins: Duplicate Item Type values | Fixed on iTwin Connector side. Requires updated Connectors (July '24 Connector Updates) |
1425209 | SPC (Structural Property Catalog) Update | Minor EULA update only |
1447616 (1457655) | Incorrect Station Values for Item Types | Values are correct in OBM, but incorrect when viewed in MicroStation, due to conversion problems. Using new expressions and updated dgn lib item types. Fix is for Abutment/Pier Cap Stations, and Approach Slab/Deck Start and End Stations. |
1430351 | Deck - Improved horizontal Point control including ability to handle sharp transitions | Set this variable in the config value OBM_USE_ADVANCED_DECK_VARIATION_ALGORITHM = TRUE to get improved accuracy on complex deck modeling. |
1456451 | Parametric Cells - Footing Reference Distance variable not working | Fixed. Model name must be the same as the file name for this to work correctly. |