OpenBridge Modeler

General Baseplate - Inner tab

Used to define dimensions and spacings for inner gusset and hole gussets.

SettingDescription
Inner Gussets
  • Inner Gussets – When checked, creates plates normal to the base plate in a direction parallel to the length of the base plate adjacent to the web of the selected shape.
    Note: Inner gussets are typically used with Web Stiffeners.
  • Number – Sets the number of plates to be created on each side of the web. The default is 0.
  • Length – Sets the plate dimension in a direction parallel to the length of the base plate. A positive value determines the length. A negative value is not permitted. A value of 0 indicates no inner gussets are to be created. The default is 0.
  • Thickness – Sets the gusset plate thickness. A positive value determines the thickness. A negative value of value of 0 is not permitted. The default is 8 or 0.25 depending on the units setting.
  • Chamfer Horiz. / Vert. – Sets the horizontal / vertical dimension for the chamfer on the plate. A positive value determines the chamfer size. A negative value is not permitted. A value of 0 for either Chamfer Horz. or Chamfer Vert. indicates no chamfer is to be created. The default is 20 or 0.75 depending on the units setting.
  • Height – Sets the plate dimension in a direction parallel to the normal of the base plate. A positive value determines the height. A negative value or a value of 0 is not permitted. The default is 100 or 4 depending on the units setting.
  • Offset – Sets the offset dimension between each of the inner gusset plates. A positive or negative value to determines the spacing. A negative value is not permitted. The default is 40 or 1.625 depending on the units setting.
Hole Gussets
  • Hole Gussets – When checked, creates plates normal to the base plate in a direction:
    • parallel to the length of the base plate adjacent to the web of the selected shape.
    • parallel to the width of the extra plate centred around the hole in the extra plate.
    Note: Enabled only when Extra Plates in Extras tab is set (other than None).
  • Spacing – Sets the distance between the inner faces of the hole gussets. The default is 40 or 1.625 depending on the units setting.
  • Thickness – Sets the gusset plate thickness. A positive value determines the thickness. A negative value of value of 0 is not permitted. The default is 8 or 0.25 depending on the units setting.
  • Chamfer Horiz. / Vert. – Sets the horizontal / vertical dimension for the chamfer on the plate. A positive value determines the chamfer size. A negative value is not permitted. A value of 0 for either Chamfer Horz. or Chamfer Vert. indicates no chamfer is to be created. The default is 10 or 0.375 depending on the units setting.