OpenBridge Modeler

Brace Splice Connection - Support tab

SettingDescription
Position Selection Sets the support position; Center, Top or Bottom.
Longitudinal Spacing Specifies the dimensions for lateral spacings at Support Side:
  • Number – Sets the number of bolts to be placed on the X axis.
  • Offset (w1) – Sets the distance from the starting edge to the center of the first bolt.
  • Distance Between (w3) – Sets the distance between the center of the bolts.
  • Slot Length – Sets the slot length.
Transverse Spacing Specifies the dimensions for vertical spacings at Support Side :
  • Number – Sets the number of bolts to be placed on the Y axis.
  • Edge Distance (g1) – Sets the distance from the edge to the center of the first bolt.
  • Distance Between (g3) – Sets the distance between the center of the bolts.
Bolts
  • Bolt Type – Sets the bolt style from the drop-down list.
  • Diameter – Sets the hole diameter of the selected bolt from the drop-down list of bolt diameter table.
  • Workloose – Sets the clearance between bolt and hole diameter.
  • Additional Length – Sets an additional length to the bolts extension outside the nut.
  • Turn – When checked, the bolt direction is inverted. Available when not welded.
  • Weld – When checked, the shapes are welded, instead of bolting.
    Note: When set to Weld, disables the Bolts and Spacing settings.