Pile Tab
The Pile Tab is not intended for use with pile design. Rather, it is used for pile reaction report.
![](GUID-5D6EA069-5682-4DA4-88FD-30BBCB119C87-low.png)
Vertical pile reactions are calculated as shown below in the following reports.
![](GUID-E73E8AED-891F-4D26-B262-584B274CDFF0-low.png)
Lateral capacity of piles without, or with batter, in both x-direction (transverse) and z-direction (longitudinal), are also calculated and checked.
![](GUID-41F47C49-13AC-4118-9279-110A07910475-low.png)